TEST MODE

To test the detection coverage:

During the TEST mode, the controlled load turns ON for 5 seconds each time the 
sensor detects occupancy.

1.  Press and hold the ON/OFF button. After 10 seconds the lighted switch fl ashes. 

The controlled load turns ON if it was not already ON. The sensor is now in 
a TEST mode that lasts 5 minutes. (You can end the TEST mode sooner by 
pressing the ON/OFF button for another 10 seconds).

2.  Move out of the coverage area or stand very still. The controlled load turns OFF 

after 5 seconds if no motion is detected.

3.  Move into the coverage area. The controlled load turns ON for 5 seconds 

each time the sensor detects motion. After 5 seconds expire without motion 
detection, the load turns OFF. The controlled load turns ON automatically with 
the next motion detection and stays ON for 5 seconds.

4.  Repeat as necessary to ensure that the desired coverage areas are within 

detection range.

TROUBLESHOOTING

Load will not turn ON (lighted switch is visible):

•  Move in front of the sensor to automatically turn lights ON. If lights do not turn 

ON, press the ON/OFF button.  The lighted switch should turn OFF and the 
controlled load should turn ON, if not:

•  Check the light bulb.

•  Make certain the circuit breaker is ON and functioning.

•  Turn OFF power to the circuit then check wire connections.

•  Remember that if the load is turned OFF manually, Automatic-ON is reenabled 

only after no motion is detected for 5 minutes.

 Light will not turn ON (lighted switch is NOT visible): 

•  Check the light bulb.

•  Make certain that the circuit breaker is ON and functioning.

•  Turn OFF power to the circuit then check wire connections.

Load will not turn OFF:

The time delay is 5 minutes (fi xed time delay).

•  Make sure no motion occurs in the coverage area until the time delay expires.

•  If the load does not turn OFF, call Technical Support at 888-817-0571.

•  Hot air currents and heat radiant devices can cause false detection. Make sure 

the sensor is at least 6 feet (2 meters) away from devices that are a signifi cant 
heat source (e.g heater, heater vent, high wattage light bulb).

•  Press the ON/OFF button. If the controlled load does not turn OFF, turn OFF 

the power to the circuit, then check wire connections.

WARRANTY INFORMATION

Watt Stopper/Legrand warranties its products to be free of defects in materials 
and workmanship for a period of fi ve (5) years. There are no obligations or 
liabilities on the part of Watt Stopper/Legrand for consequential damages arising 
out of, or in connection with, the use or performance of this product or other 
indirect damages with respect to loss of property, revenue or profi t, or cost of 
removal, installation or reinstallation.

2800 De La Cruz Boulevard, Santa Clara, CA 95050

Technical Support: 888.817.0571

www.wattstopper.com/athome

06018r2  2/2007

Please 

Recycle

Содержание WattStopprer RS-150U

Страница 1: ...tic ON is reenabled when no motion is detected for 5 minutes Time Delay The RS 150U has a fixed time delay of 5 minutes Lights will remain ON for 5 minutes after the last motion detection Coverage Area The RS 150U has a maximum range of 180 degrees and a coverage area of 600 sq feet 56 sq meters The sensor must have a clear and unobstructed view of the coverage area Objects blocking the sensor s le...

Страница 2: ...he wall box 4 Wire the sensor Twist the existing wires together with the wire leads on the RS 150U sensor as indicated below Cap them securely using the wire nuts provided See Fig 4 Connect the green or non insulated copper GROUND wire from the circuit to the green terminal on the RS 150U Connect the NEUTRAL wire from the circuit and from the lamp or fan LOAD to the white wire on the RS 150U Conne...

Страница 3: ...heck wire connections Remember that if the load is turned OFF manually Automatic ON is reenabled only after no motion is detected for 5 minutes Light will not turn ON lighted switch is NOT visible Check the light bulb Make certain that the circuit breaker is ON and functioning Turn OFF power to the circuit then check wire connections Load will not turn OFF The time delay is 5 minutes fixed time del...

Страница 4: ...tos Las luces permanecerán encendidas por 5 minutos después de la última detección de movimiento Area de Cobertura RS 150U tiene un rango de cobertura máximo de 180 grados y cubre un área de 600 pies cuadrados 56 metros cuadrados RS 150U debe poder tener visibilidad completa y sin obstrucciones del área de cobertura La carga podría apagarse aun cuando alguien se encuentre dentro del área de cobert...

Страница 5: ...ngitud Fig 3 4 Conecte el sensor Tuerza conjuntamente los cables existentes en la caja de conexiones con los cables del sensor RS 150U utilizando los conectores wire nuts provistos de acuerdo al diagrama Fig 4 Conecte el cable verde o alambre de cobre sin aislante que conecta a TIERRA a la terminal verde del RS 150U Conecte el cable de conexión a NEUTRO del circuito y de la lámpara o ventilador CA...

Страница 6: ...vise las conexiones de los cables Recuerde que si la carga es apagada manualmente la operación de ENCENDIDO APAGADO AUTOMATICO se reestablece únicamente después de que el sensor no ha detectado movimiento por 5 minutos La carga no se enciende automáticamente cuando el área es ocupada el Botón no está iluminado Revise el bombillo lámpara incandescente Asegúrese de que el disyuntor breaker del circu...

Отзывы: