INSTALLATION & WIRING

WARNING

Disconnect power to the wall switch box by turning OFF the circuit 

breaker or removing the fuse for the circuit before installing the 

RS-150U, replacing lamps, or doing any electrical work.

1.  Prepare the switch box.

 

After the power is turned OFF at the circuit 
breaker box, remove the existing wall plate and 
mounting screws. Pull the old switch out from the 
wall box.

2.  Identify the type of circuit.

 

In a Single Pole Circuit (see Fig. 2), two single 
wires connect to two screws on the existing 
switch. A ground wire may also be present 
and connected to a ground terminal on the old 
switch. 

CAUTION - FOR YOUR SAFETY: 

Connecting a proper ground to the 

sensor provides protection against electrical shock in the event of 

certain fault conditions. If a proper ground is not available, consult 

with a qualifi ed electrician before continuing installation.

 

Only connect the RS-150U to a Single Pole Circuit. 

The RS-150U is not suitable 

for 3-way switching. If the existing wiring does not match the description for a 
Single Pole Circuit, you should consult with a qualifi ed electrician.

3.  Prepare the Wires.

 

Tag the wires connected to the existing switch, 
so that they can be identifi ed later. Disconnect 
the wires. Make sure the insulation is stripped 
off the wires to expose their copper cores to the 
length indicated by the “Strip Gage,” (in Fig. 3) 
(approx. 1/2 inch). A neutral wire should also be 
present in the wall box.

4.  Wire the sensor.

 

Twist the existing wires 
together with the wire 
leads on the RS-150U 
sensor as indicated below. 
Cap them securely using 
the wire nuts provided 
(See Fig 4).

•  Connect the green or 

non-insulated (copper) 
GROUND wire from 
the circuit to the green 
terminal on the RS-150U.

• Connect 

the 

NEUTRAL 

wire from the circuit and 
from the lamp or fan 
(LOAD) to the white wire 
on the RS-150U.

•  Connect the power wire 

from the circuit (HOT) to 
the black wire on the RS-150U.

•  Connect the power wire to the lamp or fan 

(LOAD) to the red wire on the RS-150U.

5.  Put the RS-150U in the wall box. 

 

Position the lens above the ON/OFF button 
(lens at top, button at bottom) and secure it 
to the wall box with the screws provided.

6.  Attach the new cover  plate.

 

Secure it to the wall box with the screws 
provided. 

7. Restore power to the circuit. 

 

Turn ON the breaker or replace the fuse.

8.  Test the sensor’s operation.

 

See TEST MODE.

www.wattstopper.com/athome

Ground

HOT (power from

circuit box)

LOAD

(power 

to lamp)

NEUTRAL

Fig. 2: Typical Single 

Pole Switch 
Wiring

TO

P

IND

OO

R U

SE O

NLY

Green -> GROUND
Terminal

Black -> HOT (power

from circuit box)

Y

Y

White -> 
        NEUTRAL

Red -> LOAD (power

to lamp or fan)

Fig. 4: Sensor orientation, wire connections 

and wall box assembly

Strip Gage

1/2"

12.7 mm

Fig. 3: Wire Stripping

Initial Power-up Delay

There is an initial warm-up 
period the fi rst time power is 
applied to the unit and after 
a power failure lasting more 
than 5 minutes. It may take 
up to 1 minute before the 
lights turn ON. However, the 
lights can be turned ON/OFF 
manually by pressing the ON/
OFF button at any time when 
power is supplied to the unit.

Содержание WattStopprer RS-150U

Страница 1: ...tic ON is reenabled when no motion is detected for 5 minutes Time Delay The RS 150U has a fixed time delay of 5 minutes Lights will remain ON for 5 minutes after the last motion detection Coverage Area The RS 150U has a maximum range of 180 degrees and a coverage area of 600 sq feet 56 sq meters The sensor must have a clear and unobstructed view of the coverage area Objects blocking the sensor s le...

Страница 2: ...he wall box 4 Wire the sensor Twist the existing wires together with the wire leads on the RS 150U sensor as indicated below Cap them securely using the wire nuts provided See Fig 4 Connect the green or non insulated copper GROUND wire from the circuit to the green terminal on the RS 150U Connect the NEUTRAL wire from the circuit and from the lamp or fan LOAD to the white wire on the RS 150U Conne...

Страница 3: ...heck wire connections Remember that if the load is turned OFF manually Automatic ON is reenabled only after no motion is detected for 5 minutes Light will not turn ON lighted switch is NOT visible Check the light bulb Make certain that the circuit breaker is ON and functioning Turn OFF power to the circuit then check wire connections Load will not turn OFF The time delay is 5 minutes fixed time del...

Страница 4: ...tos Las luces permanecerán encendidas por 5 minutos después de la última detección de movimiento Area de Cobertura RS 150U tiene un rango de cobertura máximo de 180 grados y cubre un área de 600 pies cuadrados 56 metros cuadrados RS 150U debe poder tener visibilidad completa y sin obstrucciones del área de cobertura La carga podría apagarse aun cuando alguien se encuentre dentro del área de cobert...

Страница 5: ...ngitud Fig 3 4 Conecte el sensor Tuerza conjuntamente los cables existentes en la caja de conexiones con los cables del sensor RS 150U utilizando los conectores wire nuts provistos de acuerdo al diagrama Fig 4 Conecte el cable verde o alambre de cobre sin aislante que conecta a TIERRA a la terminal verde del RS 150U Conecte el cable de conexión a NEUTRO del circuito y de la lámpara o ventilador CA...

Страница 6: ...vise las conexiones de los cables Recuerde que si la carga es apagada manualmente la operación de ENCENDIDO APAGADO AUTOMATICO se reestablece únicamente después de que el sensor no ha detectado movimiento por 5 minutos La carga no se enciende automáticamente cuando el área es ocupada el Botón no está iluminado Revise el bombillo lámpara incandescente Asegúrese de que el disyuntor breaker del circu...

Отзывы: