Doc No. FM0862 issue 3 Page 3
Normal
Power Saving
Use a terminal
screwdriver to set
the DIP switches
ON
DIP Switch 1
–
Configuration Settings
OFF
: PIR configuration set using DIP switches 2 to 8.
ON
: PIR uses the Factory Config below and DIP switches 2 to 8 are ignored.
Function
Factory Config with DIP 1 ON
Power Saving Mode
ON
Period of no movement before new alarm
20 Secs
IDA Mode (Intelligent Door Alarm)
Disabled
IR Detection Sensitivity
High
Operation LED after Alarm
ON
Detection LED after Movement
ON
OFF Button
Enabled
Exit Delay
0 Secs
Alarm Delay
0 Secs
IMPORTANT:
with DIP 1 ON there is no entry or exit delay before alarm. The PIR must therefore be carefully positioned so a Carer
can switch the PIR on/off without entering the detection area. Poor placement in this mode is likely to result in false activations
when Carers leave or enter the room.
DIP Switch 2
–
Power Saving Mode
Transmitting alarms consumes battery power.
The PIR can be set to Power Saving Mode to extend battery life.
OFF
: normal operation, the PIR sends an alarm (Tx) after the first
movement detection (M) and will ignore new movement detections
(M) for 60 seconds before a new alarm is sent.
ON
: power saving mode, the PIR sends an alarm (Tx) after the first
movement detection (M) and there must be a period of 60 seconds
with no movement detection (M) before a new alarm is sent*.
*Note: the period of no movement is reduced to 20 seconds with the
Factory Config setting
–
DIP switch 1 ON.
DIP Switch 3
–
Intelligent Door Alarm (IDA) Mode
–
NOT USED
OFF
: normal PIR movement detection mode and DIP switch 4 is ignored.
ON
: enable IDA mode
–
feature not available with the floor PIR.
Note: DIP switches 2 and 5 are ignored if DIP switch 3 is ON.
DIP Switch 4
–
Intelligent Door Alarm (IDA) Exit Delay
–
NOT USED
In IDA mode this setting determines
the delay before an exit alarm is transmitted
–
feature not available with the floor PIR.
Note: DIP switch 4 is ignored if DIP switch 3 is OFF.
DIP Switch 5
–
PIR Detection Sensitivity
It is possible to adjust the sensitivity of the PIR detector by configuring the number of movement detection pulses that are needed
before an alarm is sent.
OFF
: high sensitivity.
ON
: low sensitivity.
DIP Switch 6
–
Operation LED indication after Alarm
OFF
: no indication when an alarm is sent.
ON
: the Operation LED will indicate when an alarm is sent.
Note: the Operation LED will always indicate during Start-up Mode and Walk Test Mode regardless of this setting.
DIP Switch 7
–
Detection LED indication after Movement
OFF
: no indication when movement is detected.
ON
: the Detection LED will indicate when movement is detected.
Note: the Detection LED will always indicate during Walk Test Mode regardless of this setting.
DIP Switch 8
–
Disable OFF Button & Alarm Delay
The function of DIP 8 depends on the position of DIP 3 (IDA mode on or off)
With DIP 3 OFF (IDA mode not activated)
–
the OFF button can be configured and alarm delays are set
DIP 8 OFF
: the PIR can be turned off with the OFF button. This means Carers can enter the room and press the OFF button within
15 seconds to prevent an alarm from being sent. By pressing the ON button when unit is in OFF mode, movement alarms are
ignored during the first 15 seconds allowing time for Carers to leave the room (i.e. when being used as a bed alarm).
DIP 8 ON
: the PIR cannot be turned off with the OFF button, this will prevent users from unintentionally turning the PIR off. There
is no alarm delay.
With DIP 3 ON (IDA mode activated)
–
the OFF button can be configured and alarm delays depend on DIP 4
DIP 8 OFF
: the door alarm can be turned off with the OFF button.
DIP 8 ON
: the door alarm cannot be turned off with the OFF button, this will prevent users from unintentionally turning the door