14
Configuration (continued)
Control of electric heating
The heating control function is used to control the
convectors in a house via a heating management
unit and CAD mains-borne signalling products.
The convectors are controlled by a CAD receptor or
by the Legrand CAD heating management unit.
Installation
The “Control of heating” commands are transmitted
via outputs or via the remote control link.
- OUT (
).
- CAD :
Each CAD product is coded with a group number
and a channel number.
On/Off mode: the On/Off orders are transmitted to
the CAD receptor which command the convectors.
Manager mode: The Omizzy™ server heating
commands are transmitted to the management unit
which passes them on to the convectors
LAN
Pow
er
7,5
- 1
2 V
1A
100
-40
0 V
~
50/6
0 H
z
1
2
1
2
3
4
CAD
I I I
SCS
100-400 V
~
50/60 Hz
CAD
SCS
Important :
Do not connect the outputs directly to the mains supply.
A power interface (contactor) must be used.
LAN
Po
we
r
7,5
- 1
2 V
1A
100
-40
0 V
~
50/6
0 H
z
1
2
1
2
3
4
CAD
I I I
SCS
N
1
2
1
2
Caution :
The zones must not be configured on the Omizzy™ server
until the heating management unit teach procedure has
been completed.
Configuring the Omizzy™ server
Click on “Installation”, “Heating”.
Click on “Add” to add and configure a new zone
(maximum two zones in manager mode).
Click on an existing zone to change its parameters.
To realise the On/Off command, fill in the fields
according to the type of product: CAD or OUT.
To realise the Manager command, there are two
possible methods for entering parameters:
Méthod 1 :
(This method is used for entering parameters remotely)
Give the heating a name.
Choose the zone and click on “Confirm”.
The group number will be filled in automatically
when the first heating command is sent from the server
to the management unit.
Compatible
products:
038 19, 038 95,
841 14, 841 17.