22
WIRING
■
Meters on the concentrator module:
Each pulse meter output is connected on
the meter side to one of the 3 concentrator
inputs. The common of these outputs
should be connected to a single terminal.
Length of cable between each
meter and the concentrator: max
1000 m - circuit resistance less
or equal to 125 Ohms or less at 25°C.
2 / 12
EMS CX
3
– Module Concentrateur
d’impulsions
Référence(s) : 4 149 26
4. MISE EN SITUATION - RACCORDEMENT
(suite)
Bornes:
. profondeur : 8 mm.
. longueur de dénudage : 8 mm
Tête de vis :
. Mixte Pozidriv fendue n°1 (UNI7596 type Z1).
Couple de serrage recommandé:
. 1 Nm.
Outils recommandés :
. Pour les bornes : tournevis Pozidriv n°1 ou à lame de 4 mm.
. Pour l’accrochage : tournevis à lame (5,5 mm maxi)
. Pour la configuration des micro-switch : tournevis à lame de 2
mm
Type de conducteur :
Câble cuivre
Sans embout
Sans embout
Câble
rigide
1 x 0,5 mm² to 1,5 mm² 2 x 1,5
mm²
-
Câble
souple
1 x 0,5 mm² to1,5 mm² 2 x 1,5
mm²
1 x 0,5 mm² to 1,5 mm² 2 x 1,5
mm²
Schéma de câblage :
Note:
. Entrées ”contacts secs” en NO (Normalement
ouvert) . Longueur de cable max. : 1000 m
. Resistance du circuit : R
max
≤ 125 Ω @ 25°C
4. MISE EN SITUATION - RACCORDEMENT
(suite)
Transmission des données EMS CX
3
(connexion des modules) :
.Par cordons communicants (réfs.4 149 07/08/09)
Permettent la transmission des données entre les différents
modules EMS CX
3
.
Ce type de connexion est recommandé lorsqu’il y a peu de modules
EMS CX
3
sur une rangée ou dans une enveloppe.
Mise en œuvre :
avec cette façon de câbler, le cache plastique
présent à l’arrière de tous les modules EMS CX
3
ne doit pas être
enlevé.
Fiche Technique : F02337FR/01
Mise à jour : -
Créée le : 21/10/2016
Ensure correct polarity of the
pulse outputs on the meters
connected to the module.
■
CX³ EMS bus:
There are 2 possible solutions for connection to the bus:
At the back of
the modules via
communication rail
Cat.Nos
4 149 01/02/03
The specifications for connection to the CX³ EMS bus are common to all CX³
EMS devices and are described in the product technical data sheets.
Downstream of the
modules via
communicating cables
Cat.Nos
4 149 07/08/09
■
Integration in optimised distribution system:
The pulse concentrator module allows the supply busbar to pass freely. Therefore, the
module can integrate HX³ optimised distribution system without modifying the parity of
the teeth.
Содержание EMS CX3
Страница 6: ...4 CX3 EMS complete compact and multifunctional MEASUREMENT SIGNALLING...
Страница 33: ...31 TECHNICAL GUIDE CX EMS Energy Management System WWW LEGRAND COM...
Страница 39: ...37 TECHNICAL GUIDE CX EMS Energy Management System WWW LEGRAND COM...
Страница 47: ...45 TECHNICAL GUIDE CX EMS Energy Management System WWW LEGRAND COM...
Страница 65: ...63 TECHNICAL GUIDE CX EMS Energy Management System WWW LEGRAND COM...
Страница 69: ...67 TECHNICAL GUIDE CX EMS Energy Management System WWW LEGRAND COM...
Страница 75: ...73 TECHNICAL GUIDE CX EMS Energy Management System WWW LEGRAND COM...
Страница 95: ...93 TECHNICAL GUIDE CX EMS Energy Management System WWW LEGRAND COM Notes...
Страница 96: ...94 Notes...
Страница 97: ...95 TECHNICAL GUIDE CX EMS Energy Management System WWW LEGRAND COM Notes...