![LEGRAND 5739 18 Скачать руководство пользователя страница 55](http://html1.mh-extra.com/html/legrand/5739-18/5739-18_installation-manual_1872047055.webp)
56
6 - Main menu
6.5.1 - Temperatures
Can set the temperature levels T1, T2, T3 and Antifreeze/Heat protection (as base the same for
all the zones) for each zone.
Press
to confirm
Press
to confirm
Press
to confirm
Press
to confirm or
to return to the
previous page, keep pressed to return to the
first page
Select
Temperature
1
2
3
5
6
9
8
7
0
4
Select ALL THE ZONES or the Zone required
(e.g.: Zone 1)
Select the temperature level to modify
(e.g.: T1)
Type the temperature required using the
number keys or using the
keys to alter
the temperature displayed by ± 0.5°C
The temperature values can be set from 3 to 40°C. To guarantee correct working of
the system the control unit automatically makes sure that T3 is higher than T2 and T2
higher than T1.
Zone state
Current profiles
Programming
Maintenance
Mode
Temperature
Summer/Winter
Date/time
Remote control
ALL ZONES
Zone1
Zone2
Zone3
T*
07.0C
T1
18.0C
T2
20.0C
T3
22.0C
T*
07.0C
T1
18.0C
T2
20.0C
T3
22.0C