7. CONFORMITIES AND APPROVALS 

Compliance to standards: 

. Compliance with Directive on electromagnetic compatibility (EMC

) n° 2014/30/EU

 

. Compliance with Radio Equipment Directive (RED

) n° 2014/53/EU

 

. Compliance with low voltage directive n° 2014/35/EU.

 

. Electromagnetic Compatibility: 
  EN 55014-1:2006 + A1:2009, Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - 
Part 1: Emission (CISPR 14-1:2005 + A1:2008) 
  EN 61000-4-2:2009, Electromagnetic compatibility (EMC) 

 Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity 

test (IEC 61000-4-2:2008) 

  EN 61000-4-3:2006 + A1:2008 + A2:2010, Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, 

radio-frequency, electromagnetic field immunity test (IEC 61000-4-3:2006 + A1:2007 + A2:2010) 

  EN 61000-4-4:2004 + A1:2010, Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast 

transient/ burst immunity test (IEC 61000-4-4:2004 + A1:2010) 

  EN 61000-4-5:2006, Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test (IEC 61000-

4-5:2005) 

  EN 61000-4-6:2009, Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted 

disturbances, induced by radio-frequency fields (IEC 61000-4-6:2008) 

  EN 61000-4-16:1998 + A1:2004 + A2:2011, Electromagnetic compatibility (EMC) - Part 4-16: Testing and measurement techniques - Test for 

immunity to conducted, common mode disturbances in the frequency range 0 Hz to 150 kHz (IEC 61000-4-16:1998 + A1:2001 + A2:2009) 

  EN 61189-2, Test methods for electrical materials, printed boSG-Es and other interconnection structures and assemblies - Part 2: Test 

methods for materials for interconnection structures (IEC 61189-2) 

  EN 61543:1995 + corr. Dec. 1997 + A11:2003 + A12:2005, Residual current-operated protective devices (RCDs) for household and similar 
use Electromagnetic compatibility (IEC 61543:1995 + A2:2005) 
. EN 50557:2011, Requirements for automatic reclosing devices (ARDs) for circuit breakers-RCBOs-RCCBs for household and similar use 
. EN 60898-1:2003 + corr. Feb. 2004 + A1:2004 + A11:2005 + A12:2008, Electrical accessories - Circuit-breakers for overcurrent protection for 
household and similar installations 

 Part 1: Circuit-breakers for a.c. operation (IEC 60898-1:2002, mod. + A1:2002, mod.) 

. EN 60898-2:2006, Electrical accessories - Circuit-breakers for overcurrent protection for household and similar installations - Part 2: Circuit-
breakers for a.c. and d.c. operation (IEC 60898-2:2000, mod. + A1:2003, mod.) 
. EN 60947-5-1:2004 + corr. Jul. 2005 + A1:2009, Low-voltage switchgear and control gear - Part 5-1: Control circuit devices and switching 
elements 

 Electromechanical control circuit devices (IEC 60947-5-1:2003 + A1:2009) 

. EN 61008-1:2004 + A11:2007 + A12:2009, Residual current operated circuit-breakers without integral overcurrent protection for household 
and similar uses (RCCBs) 

 Part 1: General rules (IEC 61008-1:1996, mod. + A1:2002, mod.) 

. EN 61009-1:2004 + A11:2008 + A12:2009 + A13:2009, Residual current operated circuit-breakers with integral overcurrent protection for 
household and similar uses (RCBOs) 

 Part 1: General rules (IEC 61009-1:1996, mod. + A1:2002, mod. + corr. May 2003) 

. EN 61558 series, Safety of power transformers, power supply units and similar products (IEC 61558 series) 
. EN 62019, Electrical accessories 

 Circuit-breakers and similar equipment for household use - Auxiliary contact units (IEC 62019) 

. Legrand devices can be used under the conditions of use as defined by IEC / EN 60947. 

Environment respect 

– Compliance with CEE directives: 

. Compliance with Directive 2011/65/UE known as "RoHS II" which provides for a restriction on the use of dangerous substances such as lead, 
mercury, cadmium, hexavalent chromium and polybrominated biphenyl (PBB) and polybrominated diphenyl ether (PBDE) brominated flame 
retardants. 
. Compliance with the Directive 91/338/EEC of 18/06/91 and decree  
94-647 of 27/07/04. 
. Compliant with regulation REACH 

Plastic materials: 

. Halogens-free plastic materials. 
. Marking of parts according to ISO 11469 and ISO 1043. 
. EN ISO 306:2004, Plastics 

 Thermoplastic materials 

 Determination of Vicat softening temperature (VST) (ISO 306:2004) 

. ISO 7000:2004, Graphical symbols for use on equipment 

 Index and synopsis 

Packaging: 

. Design and manufacture of packaging compliant to decree 98-638 of the 20/07/98 and also to directive 94/62/CE. 
 

 

 

Technical data sheet: F02465EN/01 

Updated: 28/03/2019 

Created: 06/10/2016 

 

 

 

Содержание 4 149 54

Страница 1: ...non permanent fault It reports the information through the Smartphone app Allows the user to remotely switch it ON In case of recurrent non permanent faults the Stop Go will not allow some remote comm...

Страница 2: ...e kit to connect at the downstream of the supplier indifferently in one of the two dedicated ports Supply of the Wi Fi Interface Mandatory in 12 VDC via the specific Power supply module and specific s...

Страница 3: ...install a specific protection upstream of the Stop Go because it is self protected 4 PREPARATION CONNECTION continued Wiring diagrams continued Power supply module protected by an MCB protected by a...

Страница 4: ...lip the Wi Fi module and the power supply on a different DIN row than the Stop Go module 4 PREPARATION CONNECTION continued Diagnostic procedure Once the kit assembly and the electrical connections ha...

Страница 5: ...the Stop Go the Stop Go power handle is down and the isolating handle is up and the Stop Go led flashes quickly in red 7 2 An alert message is displayed 7 3 Press on TURN ON 4 PREPARATION CONNECTION...

Страница 6: ...site information displayed by the Stop Go continued Device handle status continued Operation sequences continued In case of an Unwanted tripping of the associated device and during the verification o...

Страница 7: ...ows to remotely control the Stop Go via the Smartphone app reclosing of the associated device following a fault MAN on site manual control only by the handle of the Stop Go isolating and power handles...

Страница 8: ...rogramming mode or to restore factory settings Possible states Pressing time Action t 3 sec Wi Fi interface put in configuration mode via WPS button t 7 sec Wi Fi interface put in configuration mode v...

Страница 9: ...ne and laser marking Lateral side marking by laser left side Standard and programming information right side cabling and traceability information Technical data sheet F02465EN 01 Updated 28 03 2019 Cr...

Страница 10: ...ype Measurement type Value dBm 802 11b 1Mbps RMS 18 2 802 11g 54Mbps RMS 16 2 802 11n 72 2Mbps RMS 16 2 Characteristics of the fault detection Rd0 non operating rated resistance between the live parts...

Страница 11: ...ce against solid and liquid bodies IP 40 IEC EN 60529 Class II front panel with faceplate Resistance to sinusoidal vibrations According to IEC 60068 2 6 Axis x y z Frequency range 5 100 Hz duration 90...

Страница 12: ...ream of the associated device to the Stop Go and to protect the power supply module with a fuse holder or an MCB see Wiring diagrams Supply of the ADSL Wi Fi Box The Wi Fi module communicates with an...

Страница 13: ...1 2003 corr Feb 2004 A1 2004 A11 2005 A12 2008 Electrical accessories Circuit breakers for overcurrent protection for household and similar installations Part 1 Circuit breakers for a c operation IEC...

Страница 14: ...ing switch can be modified to 2 auxiliary contacts 1 module cat n 4 062 66 Electronic EMS CX3 Auxiliary contact Fault signalling module cat n 4 149 29 Control auxiliaries It is forbidden to associate...

Страница 15: ...ing command closing of the circuit not allowed Close manually the Stop Go 4 A too recurrent non permanent fault has been detected Remote reclosing command closing of the circuit not allowed Contact yo...

Страница 16: ...n MAN mode Remote reclosing command closing of the circuit not allowed Put selector in AUTO position 8 Stop Go in locked position Remote reclosing command closing of the circuit not allowed If it is p...

Отзывы: