background image

STYLE™

 

foundation

 

design

 99301567-d

14

REMOTE CONTROL FUNCTION

NOTE

REMOTE CONTROL REQUIRES THREE (3) AAA SIZE BATTERIES. TO CONSERVE BATTERY LIFE, THE 

TRANSMITTER TURNS OFF ALL FUNCTIONS WHEN ANY BUTTON IS PRESSED FOR MORE THAN 50 SECONDS.

TORCH BUTTON

Press and hold to use the fl ashlight 
feature.

LOCK BUTTON

To lock / unlock the remote control 
buttons, press and hold 

lock button

 for 

5 seconds. Backlight will fl ash 3 times.  

HEAD MASSAGE INTENSITY BUTTONS

Press to increase/decrease massage 

intensity. Massage has 3 speeds: 

Low, medium and high. Massage will 

automatically shut off after 15 minutes.

FOOT MASSAGE INTENSITY BUTTONS

Press to increase/decrease massage 
intensity. Massage has 3 speeds: 
Low, medium and high. Massage will 
automatically shut off after 15 minutes.

MASSAGE ON/OFF BUTTON

Press to turn massage motors on or off.

HEAD UP/DOWN BUTTONS

Press and hold to raise or lower the 

head  section.   

FOOT UP/DOWN BUTTONS

Press and hold to raise or lower the 
foot section.

 

TV POSITION BUTTON

Press to adjust the base to the 
preprogrammed TV viewing position to 
maximize comfort and entertainment. 
This position is reprogrammable using 
the 

set button

. To reprogram, adjust 

base to desired position, press and hold 
the 

set button

 until the massage motors 

turn on and off, then press and hold 
the 

tv position button

 until the massage 

motors turn on and off.

CUSTOM BUTTON

To program a position, adjust base to 
desired position, press and hold the 

set 

button

 until the massage motors turn 

on and off, then press and hold the 

cust 

button

 until the massage motors turn 

on and off.

ZERO GRAVITY BUTTON

Press to adjust the base to the 

preprogrammed reclined position for 

optimum weight distribution allowing 

total comfort and relaxation. This position 

is reprogrammable using the 

set button

To reprogram, adjust base to desired 

position, press and hold the 

set button

 

until the massage motors turn on and 

off, then press and hold the 

z grav button

 

until the massage motors turn on and off.

FLAT BUTTON

Press to adjust the base to the level position.

UNDERBED LIGHT BUTTON

Press to turn on/off underbed light feature.

WAVE BUTTON

After the head and/or foot massager/s 

have been activated and the desired 

intensity has been achieved, press to 

turn the wave on. Press to increase wave 

speed. Note: When active, wave intensity 

indicator  (shown  here)  will  light  up.             

SET BUTTON

Use to program 

z grav

tv

, and 

cust

 

presets.

  PRESS & HOLD TO ONE TOUCH

To change remote control functions from “press and hold” to “one touch” (“one touch” = press and release), simultaneously 
press the 

HEAD MASSAGE DOWN

 

and

 

FOOT MASSAGE DOWN

 

buttons for 5 seconds. The massage motor will turn on and off 

confi rming the change. Your base is now set to “one touch.”
When in “one touch” mode:

Zero Gravity, Custom, and TV Position buttons

Press and release (one touch) button. Base will adjust to the programmed position. Press any other button to stop the base during movement.

Flat button

Press and release (one touch) button. Base will shut off massage motor, if active, and adjust base to level position. Press any other 
button to stop the base during movement.
To revert back to 

factory settings

, simultaneously press and hold the 

SET 

button and the 

FLAT

 

button for 5 seconds. The massage 

motor will turn on and off confi rming the change. Your base is now set to factory settings. 

Note: Zero Gravity and TV Positions will 

revert to factory preprogrammed positions.

Содержание style series

Страница 1: ...STYLE FOUNDATION DESIGN owners manual 1 PIECE MODELS ENGLISH SPANISH FRENCH ...

Страница 2: ...g 15 Troubleshooting 17 1 3 25 Warranty 18 CONTENTS If adjustable base does not operate or if parts are missing call 800 888 3078 Do not contact retail store or dealer Spanish translation begins on page 20 La traducción en español inicia en la página 20 French Canadian translation begins on page 38 La traduction en Français débute à la page 38 ...

Страница 3: ...lift motors are not designed for continuous use Reliable operation and full life expectancy will be realized as long as lift motor operation does not exceed five 5 minutes over a thirty 30 minute period or approximately 15 duty cycle Note Massage equipped bases are not designed for continuous extended massage operation Massage systems are rated for a maximum of 2 hours of use within any 6 hour per...

Страница 4: ...the instruction manual may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the followi...

Страница 5: ...d floor with the massage feature in operation a vibrating tone will be audible To minimize this resonance place a piece of carpet or rubber caster cups under each leg or caster of the base It is possible to experience vibration or noise from the headboard brackets headboards or footboards if mounting bolts are not firmly tightened FABRIC CLEANING INFORMATION Spot clean only with water based shampo...

Страница 6: ... 2 Corner Mattress Retainers w bushings per base 4 Legs 2 Headboard Bracket Assemblies 1 Headboard Bracket Hardware Kit blister card 1 Remote Control w 3 AAA batteries 1 Power Down Box 1 Dual Sync Cable TXL bases only 1 Warranty Activation Card 1 Quick Setup Guide WARRANTY ACTIVATION CARD HEADBOARD BRACKET ASSEMBLIES HARDWARE 4 bracket pieces hardware blister card Blister Card LEG 4 pieces QUICK S...

Страница 7: ...stic packaging to prevent base from becoming soiled from the shipping carton keeping the unit top side down Remove and extend out power cord from base LEGS SCREW INTO TAPPED HOLE AT EACH CORNER FIGURE 1 AT LEAST TWO PEOPLE ARE RECOMMENDED FOR HANDLING AND MOVING ADJUSTABLE BASE DO NOT ATTEMPT TO SCREW LEGS INTO ANY OTHER INSERTS THIS WILL DAMAGE PRODUCT POWER CORDS MUST NOT INTERFERE WITH ANY ADJU...

Страница 8: ...ll functions of the base with the remote control to verify all features are in working order If base does not operate refer to the Troubleshooting section of this manual BATTERY COMPARTMENT DOOR PRESS IN ON TAB AND LIFT OUT TO REMOVE BATTERY COMPARTMENT DOOR INSERT TABS IN TAB SLOTS AND SNAP IN TO REPLACE POSITIVE END POSITIVE END STEP 7 Return base to the level position STEP 8 Remove the plastic ...

Страница 9: ...r mattress retainers at the foot end of the adjustable base as follows a Locate by feel corner holes underneath base cover at foot end of base FIGURE 3 CORNER MATTRESS RETAINER TWO PRONGED BUSHING FIGURE 4 b Insert two pronged bushing into holes in corner mattress retainer Press bushing through material into holes until retainer fits securely against base FIGURE 4 CORNER MATTRESS RETAINER INSTALLE...

Страница 10: ... IN ORDER TO AVOID A PERSON OR PET BEING CAUGHT IN THE SPACE REFERENCED BELOW WHILE THE BASE IS IN MOTION THE BOTTOM OF THE HEADBOARD CROSS MEMBER MUST BE POSITIONED SO THAT THERE IS NO MORE THAN 3 INCHES 76 2mm BETWEEN THE HEADBOARD AND THE TOP OF THE MATTRESS FIGURE 5 DO NOT EXCEED 3 INCHES 76 2mm FAILURE TO FOLLOW THIS INSTRUCTION COULD RESULT IN SERIOUS PERSONAL INJURY OR DEATH WARNING WARNING...

Страница 11: ... Using the remote control raise the head section of the base as far as it will articulate to gain access to the adjustable base frame b Slide one headboard bracket channel onto one side of the base frame Using 2 carriage bolts nuts attach channel to base frame FIGURE 6 Hand tighten bolts nuts loosely to allow adjustment of the headboard bracket channels Repeat procedure to install the other headbo...

Страница 12: ...FLANGE USE 2 1 INCH LONG HEX HEAD BOLTS AND NUTS TIGHTEN TO ATTACH BRACKET FLANGE TO BRACKET CHANNEL SLIDE BRACKET ASSEMBLIES IN OR OUT TO ACHIEVE POSITION FIGURE 7 e Firmly tighten the 3 inch carriage bolts of both headboard bracket channels f Measure the distance center to center between the mounting holes in the headboard g Measure the center to center distance between the mounting slots of the...

Страница 13: ...ox FIGURE 8 Install 2 9 volt batteries not included in power down box FIGURE 8 STEP 2 Press the lowering button on the power down box FIGURE 8 to lower the base to the flat position FIGURE 8 POWER DOWN BOX LOWERING BUTTON INSTALL 2 9 VOLT BATTERIES NOT INCLUDED STEP 3 Remove two 2 9 volt batteries from power down box When power is restored from outage base is ready to resume normal operation ...

Страница 14: ...ess to adjust the base to the preprogrammed reclined position for optimum weight distribution allowing total comfort and relaxation This position is reprogrammable using the set button To reprogram adjust base to desired position press and hold the set button until the massage motors turn on and off then press and hold the z grav button until the massage motors turn on and off FLAT BUTTON Press to...

Страница 15: ...oes off STEP 5 Operate remote control to verify programming One remote control is now programmed to operate one base FIGURE 9 LEARN SWITCH BATTERY COMPARTMENT DOOR STEP 2 Make sure adjustable base is plugged into electrical power source Position base on its side Locate the power down device FIGURE 10 STEP 3 Push the power down reset button in two times in rapid succession FIGURE 10 The underbed li...

Страница 16: ...ing the remaining male and female plugs of the dual sync cable STEP 7 Turn both bases over so they are resting on their legs CAUTION MAKE SURE CABLE IS CLEAR OF BASE AND FREE OF ANY PINCH POINTS STEP 8 Plug both bases into electrical power source STEP 9 Operate both bases with the remote control NOTE If bases do not operate in unison with the remote verify dual sync cable connections are fully sea...

Страница 17: ...adboard may be too close the edge of the mattress Verify a 1 5 38 1mm to 2 50 8mm distance between headboard brackets and mattress Adjust if required Verify headboard brackets were removed during installation Remove headboard brackets if still attached to the underneath side of base If base is located on hard surface flooring place carpet pieces or rubber caster cups under each leg or caster of th...

Страница 18: ...the number of months that the base has been owned by you since the fourth anniversary of the Warranty Commencement Date By the end of the 25th year no portion of the replacement cost is covered by L P You will be required to pay 1 22nd of the then current replacement cost of the part multiplied by the number of years past the third year from the Warranty Commencement Date This portion is calculate...

Страница 19: ...o lack of accessibility the service call will be billed to You and the service will have to be rescheduled L P makes no other warranty whatever express or implied and all implied warranties of merchantability and fitness for a particular purpose are disclaimed by L P and excluded from this agreement Some American States do not allow the exclusion or limitation of incidental or consequential damage...