![Legato SMS Basic Скачать руководство пользователя страница 31](http://html.mh-extra.com/html/legato/sms-basic/sms-basic_user-manual_1868833031.webp)
GSM SMS Alarm Messenger
SMSPro (Version 7)
31
PWD:XXXX,PARAMETER
2
%
[SMS Message received]
ST:XXX;
VL:
XXXX,
O:
AX,BBBBBBBB,CCC;
A1M:XXXXX,UUUUU,YYYYY,R,HHHHH,PPPPP,O:A
X,BBBBBBBB,CCC;A2M:XXXXX,UUUUU,YYYYY,R,HHHHH,PPPPP,O:AX,BBBBBBBB,CCC
;
#
VL
Min. Operating Voltage, below this level will trigger alarm
7VDC by default
A
alarm report to Control Centre 1
0 means no report
1 means report
X
alarm report to Control Centre 2
0 means no report
1 means report
BBBBBBBB
report status for 8 phone numbers
0 means no report
1 means “SMS” but no “phone dialing”
2 means “phone dialing” but no “SMS”
3 means “SMS” and then “phone dialing”
CCC
relay output control
0 means relay is not controlled by low voltage alarm
1 means relay is turned on by low voltage alarm