![Legato SMS Basic Скачать руководство пользователя страница 27](http://html.mh-extra.com/html/legato/sms-basic/sms-basic_user-manual_1868833027.webp)
GSM SMS Alarm Messenger
SMSPro (Version 7)
27
11.15)
Input Voltage Low Level Alarm
This command is to set the action to be done once the operating voltage drops below
the preset value. Value of current operating voltage can be retrieved by the command 2.
Command: PWD:
XXXX
,ADCOUT
0
:
YY,ZZZZBBBB,NNN
%
XXXX Password
YY
00 means alarm not report to Control Centre
10 means alarm report to Control Centre 1
01 means alarm report to Control Centre 2
11 means alarm report to Control Centre 1 and 2
ZZZZBBBB
Selection of alarm phone dial and alarm SMS
0 means no alarm report
1 means “SMS” only
2 means “phone dial” only
3 means “SMS” first, and then “phone dial”
Z Z Z Z
B B B B
NNN Relay
Output
Control
0 means no relay output control
1 means relay output triggered by alarm
N N N
1
st
phone number
2
nd
phone number
3
rd
phone number
4
th
phone number
1
st
Relay Control
2
nd
Relay Control
3
rd
Relay Control
5
th
phone number
6
th
phone number
7
th
phone number
8
th
phone number