Entry Control Command Class
A)
Entry Control Key Supported Report Command
Key
Description
0
Keypad Number 0
1
Keypad Number 1
2
Keypad Number 2
3
Keypad Number 3
4
Keypad Number 4
5
Keypad Number 5
6
Keypad Number 6
7
Keypad Number 7
8
Keypad Number 8
9
Keypad Number 9
B)
Entry Control Event Supported Report Command
Data Type:
Data Type
Description
0x02
1 to 32 ASCII encoded characters. ASCII codes MUST be in the value range 0x00-0xF7. The string
MUST be padded with the value 0xFF to fit 16 byte blocks when sent in a notification.
Event Type:
Event Type
Button label
Description
0x00
Caching
CACHING KEYS is sent when the user has started entering credentials
0x01
Cached
CACHED_KEYS is sent when the cache size or the cache timeout is exceeded
0x02
ENTER
Keypad will sent entry control notification (event type=0x02)when the
“√”button is pressed.
0x03
DISARM_ALL
Keypad will sent entry control notification (event type=0x03)when the
Home Mode button is pressed.
0x05
ARM_AWAY
Keypad will sent entry control notification (event type=0x05)when the
Away Mode button is pressed.
0x06
ARM_HOME
Keypad will sent entry control notification (event type=0x06)when the