Indicator Set Command
1.
Set display status state to the Keypad, received from a Z-wave gateway
2.
Indicator has 1 byte payload that is defined for the keypad in the following manner
7
6
5
4
3
2
1
0
Status Modifier
Status States
Status Modifier:
Status Modifier for Entry Delay and Exit Delay is a time field that defines how long to run the state
feedback, Defined Time Field Status
Modifier use:
0x0 = 0sec
0x1 = 10sec
0x2 = 20sec
0x3 = 30sec
...
0xE = 140sec
0xF = 180sec
Status Modifier for Alarming is an alarm type identifier that enables the keypad to indicate which alarm
event the system has detected, Defined Alarming Status Modifier:
Status Modifier for Armed Stay, Armed Away, Disarmed, Bypass Challenge, and Input Reject is a field that
defines if the keypad should play sound, and if the keypad should light up upon receiving status. The
modifier is a bit encoded field with:
0x0 = Sound ON and Activate LEDs (Normal Operation) for status update
0x1 = Sound OFF and Activate LEDs for status update
0x2 = Sound ON and Do Not Activate LEDs for status update
0x3 = Sound OFF and Do Not Activate LEDs for status update
Status States :
Status Modifier
Description
0x00
Alarm Event - Default