8
Tampering, Product covering removed (0x03): the temper button is released.
Previous Events cleared (0x00): the temper button is pressed.
Power Management:
Replace Battery Soon (0x0a): When Door/Window sensor first detect the battery level is lower than
the level of low battery (see the configuration parameter NO.10 below).
Replace Battery Now (0x0b): When Door/Window sensor first detect the battery level is lower than
5%.
Previous Events cleared (0x00): When Door/Window sensor powered by a new battery (>2.8V).
9.2.4 Configuration Command
Door/Window Sensor offers a wide variety of advanced configuration settings. Below parameters can be
accessed from main controllers configuration interface.
NOTE: ALL NUMBERS BELOW ARE DECIMAL.
Parameter No.10 Level of low battery
This parameter defines a battery level as the “low battery”.
Available settings:
0-50 (0% - 50%)
Default setting:
10 (10%)
Parameter size:
1[byte]
Parameter No.14 Enable/Disable BASIC SET command
Door/Window Sensor can send BASIC SET command to nodes associated with group 2.
0
– Disable.
1
– Enable.
Default setting:
0
Parameter size:
1 [byte]
Parameter No.15 Value of the BASIC SET
Door/Window Sensor can reverse its value of BASIC SET when the magnet is triggered.
0
–Send BASIC SET VALUE = 255 to nodes associated with group 2 when door/window is opened.
Send BASIC SET VALUE = 0 to nodes associated with group 2 when door/window is closed.
1
–Send BASIC SET VALUE = 0 to nodes associated with group 2 when door/window is opened.
Send BASIC SET VALUE = 255 to nodes associated with group 2 when door/window is closed.
Default setting:
0
Parameter size:
1[byte]
Parameter No.254 Enable/disable the configuration command
Lock/unlock all configuration parameters.
0
– Unlock.
1
– Lock.
Default setting:
0
Parameter size:
1[byte]