7
COMMAND_CLASS_SUPERVISION_V1
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V4
Security
Supported
Report
Command
Classes
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_VERSION_V2
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_BATTERY_V1
COMMAND_CLASS_NOTIFICATION_V8
COMMAND_CLASS_WAKE_UP_V2
COMMAND_CLASS_SUPERVISION_V1
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V4
9.2. NOTE FOR SPECIAL COMMANDS
9.2.1 Association Command
Door/Window Sensor supports two association groups.
Grouping
Identifier
Max
Nodes
Send Commands
Group 1
0x05
1. Notification Report.
Sensor will send Notification Report when the supported
event is triggered.
2. Battery Report.
Sensor will send Battery Report when the battery level is
low and the battery report’s value is 0xFF.
3. Device Reset Locally.
Group 2
0x05
1.Basic Set
Sensor will send Basic Set when the sensor body and
magnet removed or combined.
9.2.2 Basic Command
There is no relevant commands are available for mapping.
9.2.3 Notification Command
1. Notification Supported Report;
There are three types notifications are supported, Access Control (0x06), Home Security (0x07) and
Power Management (0x08).
2. Event Supported Report;
Access Control: Window/Door is open (0x16), Window/Door is closed (0x17).
Home Security: Tampering, Product covering removed (0x03), Previous Events cleared (0x00).
Power Management: Replace Battery Soon (0x0a), Replace Battery Now (0x0b), Previous Events
cleared (0x00).
3. How to trigger the different notifications;
Access Control:
Window/Door is open (0x16): the separation of the main body and the magnet.
Window/Door is closed (0x17): the combination of the main body and the magnet.
Home Security: