7.3.2 Configuration Command Parameters
Multi-Sensor offers a wide variety of advanced configuration settings. Below parameters can be accessed
from main controllers configuration interface.
Parameter
Size
Default Value
Description
10
(0x0A)
1
0x0A
Low Battery Power Level of alarm threshold values:
the value range are 10~50 for percentage, so the
Battery Low Power level can setting
10%~50%
.
12
(0x0c)
1
0x0A
Turn on/off PIR 0x0A indicates the highest
sensitivity, 0x00 means off PIR detection function.
Valid values:
0x00-0x0A
13
(0x0d)
2
0x1e
PIR triggers the waiting time value
,
Valid values:
0x05-0x3BC4
14
(0x0e)
1
0x00
Whether the BASIC SET command is sent after the
PIR is triggered
0 = Unable
1 = Enable
15
(0x0f)
1
0
PIR triggers the correspondence between the value
of the Basic set and the PIR state, When value is
0x00 PIR triggers Send the basic set command 0xff
PIR alarm release send the basic set command
0x00, otherwise PIR triggers send the basic set
command 0x00 PIR alarm release send the basic
set command 0xff.
Valid values:0-1
100
(0x64)
1
NA
Set 101 ~ 104 to default.
101
(0x65)
4
0x1C20
The interval time of sending the temperature
reporting. if setting to
0
then the
temperature
reporting
is disabled
1. Valid values:
0x00-0x28DE80
2. The minimum interval time is 1 minutes. For
example, if the value is set to be more than 1 and
less than 60, the interval time is 1 minutes, if the
value is set to be more than 60 and less than 120,
the interval time is 2 minutes.
102
(0x66)
4
0x1C20
The interval time of sending the humidity
reporting. if setting to
0
then the
humidity
reporting
is disabled
1. Valid values:
0x00-0x28DE80
2. The minimum interval time is 1 minutes. For
example, if the value is set to be more than 1 and
less than 60, the interval time is 1 minutes, if the
value is set to be more than 60 and less than 120,