8
Association setting and restore the Configuration setting to
the default.
Caution:
This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
Changes or modifications not expressly approved by the party responsible for compliance could void the
user's authority to operate the equipment.
Hereby, Corporation declares that this device is in compliance with the essential requirements and other
relevant provisions of Directive 2014/53/EU
7.2
Low voltage alarm to remind changing battery.
This product has low voltage detection reminder, when the battery voltage is in low status, the
detector will give out low battery signal to controller.
7.3
Z-Wave command.
7.3.1 Association Command
Multi-Sensor supports two association groups.
Grouping Identifier
Max Nodes
Transmit Content
Group 1
0x05
1. Notification Report.
Sensor will send Notification Report when Motion
Detection Unknown Location and (Event inactive).
2. Multilevel Sensor Report
Sensor
will
send
Multilevel Sensor
Report
(Temperature, humidity, luminance) interval of 2 hours.
3. Battery Report.
Sensor will send Battery Report when the battery level
is low and the battery report’s value is 0xFF.
4. Device Reset Locally.
Group 2
0x05
Send Basic Set when PIR trigger