Setting the DMX address:

The DMX mode enables the use of a universal DMX controller. Each fixture requires a “start address” 
from 1- 511. A fixture requiring one or more channels for control begins to read the data on the channel 
indicated by the start address. For example, a fixture that occupies or uses 7 channels of DMX and was 
addressed to start on DMX channel 100, would read data from channels: 100,101,102,103,104,105 
and 106. Choose a start address so that the channels used do not overlap. E.g. the next unit in the 
chain starts at 107.

DMX 512:

DMX (Digital Multiplex) is a universal protocol used as a form of communication between intelligent 
fixtures and controllers. A DMX controller sends DMX data instructions form the controller to the fixture. 
DMX data is sent as serial data that travels from fixture to fixture via the DATA “IN” and DATA “OUT”  
XLR terminals located on all DMX fixtures (most controllers only have a data “out” terminal).

DMX linking:

DMX is a language allowing all makes and models of different manufactures to be linked together  
and operate from a single controller, as long as all fixtures and the controller are DMX compliant.  
To ensure proper DMX data transmission, when using several DMX fixtures try to use the shortest  
cable path possible. The order in which fixtures are connected in a DMX line does not influence the  
DMX addressing. For example; a fixture assigned to a DMX address of 1 may be placed anywhere in  
a DMX line, at the beginning, at the end, or anywhere in the middle. When a fixture is assigned a  
DMX address of 1, the DMX controller knows to send DATA assigned to address 1 to that unit,  
no matter where it is located in the DMX chain.

DATA cable (DMX cable) requirements (for DMX operation):

This fixture can be controlled via DMX-512 protocol. The DMX address is set on the back of the unit. 
Your unit and your DMX controller require a standard 3-pin XLR connector for data input/output,  
see image below.

Note: DMX cable must be daisy chained and cannot be split.

DMX setup

Further DMX cables can be 

purchased from all good sound 

and lighting suppliers or  

Pro Light Concepts dealers.
Please quote:

CABL10 – 2m
CABL11 – 5m
CABL12 – 10m

Содержание Rubix RGB 3D Panel

Страница 1: ...Order code LEDJ476 Rubix RGB 3D Panel User Manual...

Страница 2: ...in short intervals as this will reduce the system s life Only use the equipment indoors Do not expose to flammable sources liquids or gases Always disconnect the power from the mains when equipment is...

Страница 3: ...ng these ideal for night clubs entertainers or on stage The Rubix also features full pixel mapping capability for integration into larger systems Rubix RGB 3D Panel 434mm 116mm 500mm 108 tri colour SM...

Страница 4: ...tion omega clamp 1 x connection omega clamp 1 x PowerCON cable 1 x user manual www prolight co uk Rubix RGB 3D Panel MENU ENTER UP DOWN www prolight co uk Rubix RGB 3D Panel POWER INPUT 100 240V 50 60...

Страница 5: ...S p 0 1 S p F L P r 0 2 P r 2 8 P r o A U T O Auto mode S L A v Slave mode C o L r Colour mix mode r 1 0 0 r 2 0 0 r 3 0 0 r 1 F L r 2 F L r 3 F L g 1 0 0 g 2 0 0 g 3 0 0 b 1 0 0 b 2 0 0 b 3 0 0 g 1...

Страница 6: ...ng instructions MENU u e r I n F o u Software version S e t C u r S y n c r S t F A I L C u 1 C u 4 Dimming curve selection O f f H o L d DMX signal failure 0 n O f f DMX sync setting N O y E s Reset...

Страница 7: ...gment 3 dimmer 0 100 8 000 255 Green segment 3 dimmer 0 100 9 000 255 Blue segment 3 dimmer 0 100 9 channel mode Channel Value Function 1 000 255 Master dimmer 0 100 2 000 255 Red dimmer 0 100 3 000 2...

Страница 8: ...0 Pixel 6 Red 0 100 Pixel 6 Green 0 100 Pixel 6 Blue 0 100 Pixel 7 Red 0 100 Pixel 7 Green 0 100 Value CH71 CH72 CH73 CH74 CH75 CH76 CH77 CH78 CH79 CH80 000 255 Pixel 24 Green 0 100 Pixel 24 Blue 0 10...

Страница 9: ...0 Pixel 6 Green 0 100 Pixel 6 Blue 0 100 Pixel 7 Red 0 100 Value CH71 CH72 CH73 CH74 CH75 CH76 CH77 CH78 CH79 CH80 000 255 Pixel 24 Red 0 100 Pixel 24 Green 0 100 Pixel 24 Blue 0 100 Pixel 25 Red 0 10...

Страница 10: ...xel 8 Green 0 100 37 000 255 Pixel 8 Blue 0 100 38 000 255 Pixel 9 Red 0 100 39 000 255 Pixel 9 Green 0 100 40 000 255 Pixel 9 Blue 0 100 98 channel mode Channel Value Function 41 000 255 Pixel 10 Red...

Страница 11: ...hange 13 152 159 Program 19 Change 14 160 167 Program 20 Change 15 168 175 Program 21 Change 16 176 183 Program 22 Change 17 184 191 Program 23 Change 18 192 199 Program 24 Change 19 200 207 Program 2...

Страница 12: ...ss the MENU button on the rear of the master unit then select your desired program sound active auto static pattern or one of the built in programs To set the other units in slave mode press the MENU...

Страница 13: ...se the UP and DOWN buttons on the rear of the unit to show Set on the LED display Press the ENTER button and then use the UP and DOWN buttons to select Sync Press the ENTER button and then use the UP...

Страница 14: ...DMX is a language allowing all makes and models of different manufactures to be linked together and operate from a single controller as long as all fixtures and the controller are DMX compliant To en...

Страница 15: ...9 5 pin XLR DMX connectors Some manufactures use 5 pin XLR connectors for data transmission in place of 3 pin 5 pin XLR fixtures may be implemented in a 3 pin XLR DMX line When inserting standard 5 pi...

Страница 16: ...ssible harm to the environment or human health from uncontrolled waste disposal please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material...

Отзывы: