10 | BA MECHALED . BA 03/2019
5 | Connection
The LED-luminaire is delivered with a preassembled 3m sensor cable, PUR, and M12
connector, A coded, at the end. Suitable connection material, cables and accessories
can be found in the accessory range of LED2WORK.
4 | Assembly, Mounting and Optics exchange
Check the LED luminaire before installation to ensure it is complete and shows no
signs of damage. Do not use the luminaire or accessories if they are damaged, as
there is a risk of injury.
The LED luminaire comes fully assembled - with 10° optics for spotlight. the 25° optics
lens for scattered light is attached. According to varint, the luminaire is attached via
magnet or srew-on base.
Optics exchange:
Remove the plastic cap nut form top of the luminaire. Carefully
remove the glass cover. Now you can exchange the lenses including the holding ring.
Do not touch the LEDs!
Take care when installing the changeable optics for a correct
-
ly positioning - do not apply any pressure. Close the glass cover with the cap nut. Take
care for a correctly positioning of o-ring gasket under the glass cover.
Optional there is follow accessories for this luminaire:
Item no.
Protection glass, clear (1 pcs. including delivery)
220400-01
Protection glass, opal white
220400-02
Dimmable with build-in push-button -
made to order
999999-10
When mounting the luminaire, make sure that the luminaire is
fastened securely and stably. If the luminaire falls down, its weight
poses a risk of
injury!
3 | Safety information
Danger of electric shock!
Disconnect before working on the
device or load. Ensure to disconnect all circuit breakers that supply
dangerous voltages to the device or load, when doing so. Even
when the device is switched off, the load is not galvanically isolated
from the mains.
Only use the device if it is completely free of faults, and with safety
and awareness in mind.
If warnings or symbols are attached to the luminaire, they must not
be removed.