Reference Manual
Rio Rancho, NM
37
Command Description
incpatt
Input compressor attack time
incpgn
Input compressor gain
incpmug
Input compressor makeup gain
incprat
Input compressor ratio
incprel
Input compressor release time
incpthr
Input compressor threshold level
NOTE: All commands are terminated with an
ASCII carriage return character (hex code 0x0D),
represented by <CR> in the examples. All
responses are terminated with an ASCII carriage
return, line feed pair (hex codes 0x0D, 0x0A),
represented by <CRLF> in the examples. An
ellipsis (...) represents members of an array that
have been omitted from an example for the sake
of brevity.
incpatt (input compressor attack time)
This command is used as a query to read the attack
time, or as an update to set the attack time. The input
channel is specified by using the address syntax. Ad-
dresses must be in the range 1 to 16. The data type is
integer, in the range 5 to 2000, representing the time in
one tenth millisecond increments.
Examples:
Request
Response
Query
incpatt(1)?<CR>
OK 42<CRLF>
Update
incpatt(15)=30<CR> OK<CRLF>
incpgn (input compressor gain)
This command may be used as a query to read the
compressor gain. The input channel is specified by using
the address syntax. Addresses must be in the range 1 to
16. The data type is integer, representing the gain in dB,
which is always a negative value if the compressor is ac-
tive, or zero.
Example:
Request
Response
Query
incpgn(1)?<CR>
OK -5<CRLF>
incpmug (input compressor makeup gain)
This command is used as a query to read the makeup
gain, or as an update to set the makeup gain. The input
channel is specified by using the address syntax. Ad-
dresses must be in the range 1 to 16. The data type is
integer, in the range 0 to 30, representing the gain in
dB. The allowable upper limit of makeup gain values
is dynamically determined by the threshold and ratio
settings of the compressor, and may be less than the
absolute maximum of 30 dB. If the value sent in an
update request exceeds this upper limit, it will be forced
to the limit value.
Examples:
Request
Response
Query
incpmug(1)?<CR>
OK 5<CRLF>
Update
incpmug(15)=12<CR> OK<CRLF>
incprat (input compressor ratio)
This command is used as a query to read the ratio, or
as an update to set the ratio. The input channel is speci-
fied by using the address syntax. Addresses must be
in the range 1 to 16. The data type is float, in the range
0.0 to 50.0, representing the compression ratio, with 0.0
meaning that the compressor is “off”.
Examples:
Request
Response
Query
incprat(1)?<CR>
OK 2.1<CRLF>
Update
incprat(15)=5.55<CR> OK<CRLF>
incprel (input compressor release time)
This command is used as a query to read the attack
time, or as an update to set the attack time. The input
channel is specified by using the address syntax. Ad-
dresses must be in the range 1 to 16. The data type
is integer, in the range 100 to 10000, representing the
time in one tenth millisecond increments.
Examples:
Request
Response
Query
incprel(1)?<CR>
OK 500<CRLF>
Update
incprel(15)=2000<CR> OK<CRLF>
incpthr (input compressor threshold level)
This command is used as a query to read the threshold,
or as an update to set the threshold. The input channel
is specified by using the address syntax. Addresses
must be in the range 1 to 16. The data type is integer, in
the range -80 to +20, representing the level in dBu.
Examples:
Request
Response
Query
incpthr(1)?<CR>
OK -3<CRLF>
Update
incpthr(15)=-20<CR> OK<CRLF>
DM1624F Input Compressor Commands
Содержание DM812
Страница 2: ...DM Series Digital Matrix Processors LECTROSONICS INC 2 ...
Страница 50: ......