Lectrosonics DM812 Скачать руководство пользователя страница 1

DM Series

Digital Audio Processors

Models:

DM1624F

DM1612F

DM812

Firmware Versions 1.5.0 and higher

REFERENCE MANUAL

Rio Rancho, NM, USA

www.lectrosonics.com

Fill in for your records:

  Serial Number:

  Purchase Date:

Содержание DM812

Страница 1: ...Series Digital Audio Processors Models DM1624F DM1612F DM812 Firmware Versions 1 5 0 and higher REFERENCE MANUAL Rio Rancho NM USA www lectrosonics com Fill in for your records Serial Number Purchase Date ...

Страница 2: ...DM Series Digital Matrix Processors LECTROSONICS INC 2 ...

Страница 3: ...and third grounding prong The wider blade or the third prong are provided for your safety If the provided plug does not fit into your outlet consult an electri cian for replacement of the obsolete outlet 10 Protect the power cord from being walked on or pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus 11 Only use attachments accessories specifi...

Страница 4: ...s 19 Command View Screen 21 Serial Port Speed Adjustment 21 Installing LecNet2 Software and USB Driver 23 Installation with LecNet2 Device Installer 23 Manual Installation 24 Firmware Updates 25 Using the Update Wizard 25 Serial Interface and Control Commands 28 Wildcards 28 Differences between DM units 28 DM General Commands 28 DM1624F Audio Input Commands 31 DM1624F Matrix Crosspoint Commands 33...

Страница 5: ...k noise generator or the tone generator as needed for setup diagnostics or operation Each of the 24 outputs includes extensive signal processing to optimize the mixed signal for the intended purpose such as sound reinforcement recording or teleconferencing Multiple units can be stacked together using the Digi tal Audio Network Interface DANI DANI connects the digital audio outputs of the master an...

Страница 6: ... Out 7 Out 6 Out 5 Out 4 Out 3 Out 2 Out 12 Out 11 Out 10 Out 20 Out 19 Out 18 Out 17 Out 16 Out 15 Out 14 Out 13 Out 24 Out 23 Out 22 Out 21 Signal Processing D A Out Atten M S Signal Processing D A Out Atten M S Signal Processing D A Out Atten M S Signal Processing D A Out Atten M S Signal Processing D A M S Signal Processing D A M S Signal Processing D A M S Signal Processing D A M S Signal Pro...

Страница 7: ...c feed back that may occur Applying ADFE at the input rather than at the output allows the filters to deal exclusively with the unique characteristics of the individual input channel rather than with the composite of multiple chan nels that appear at any one output Compressor A sophisticated compressor stage is provided following the other stages to control the dynamic characteristics of the input...

Страница 8: ... the signal received from that input does not actually appear in the mix at that output NOTE The M S master slave switch selects the signal that the output channel will deliver when the unit is operating as a slave in a stacked configuration NOTE certain output channels provide an attenuator to reduce the signal to microphone level IMPORTANT Even though the output level adjustment provides up to 7...

Страница 9: ... comb filtering and improve intelligibility Filters Up to nine filters can be implemented at each output to idealize the output channel equalization and implement crossover networks for bi amped or tri amped loud speaker systems The filter types include Low pass High pass Band pass Parametric EQ Low shelving High shelving Filter slopes can be selected with 6 or 12 dB per octave Butterworth or Bess...

Страница 10: ...te a DM system or provide feedback on system operation PUSH FOR MENU SELECT Rotary Control The PUSH FOR MENU SELECT rotary control is used to select a menu submenu or setup screen and for selecting or setting operating parameters This control is often used for minor tweaking after the original setup has been downloaded from a computer system via the USB port USB Port Standard USB Version 1 1 conne...

Страница 11: ...nies USB Port Standard USB Version 1 1 connector for setup and con trol of the DM from a Windows based computer system with USB interface Programmable Input and Output Ports Programmable inputs or outputs used to enable control over a variety of parameters or to indicate either chan nel activity or the current state of a programmable input DANI DANI or Digital Audio Network Interface is used to co...

Страница 12: ...This interface is used mainly for minor adjustments to rear panel input and output levels The GUI is used for other functions such as system setup and control Rotary encoder control Rotate to highlight a menu item or adjust operating parameter and press to enter a submenu or setup screen BACK button used to return to previous menu Item select buttons used on setup screens NOTE Adjustments made wit...

Страница 13: ...e operating parameters for the system s inputs mixing matrix and outputs A fourth item on the list is used to set the system as a Master or Slave unit Ro tate the PUSH FOR MENU SELECT control to highlight an item on the list then press the control to select that item Setup Screens The Setup Screens are used to change system operat ing parameters for the selected channels The Setup Screen will disp...

Страница 14: ...ore moving to the following steps RP Gain RPG is used to view or change the attenuation ap plied to the rear panel input for the selected analog input channel Select RPG by pressing the Item Select Button below RPG Rotate the PRESS FOR MENU SELECT control until the desired Rear Panel Gain is displayed in the Parameter Display Area This setting is normally controlled by hardware such as variable re...

Страница 15: ...dB in 1 dB increments PhanPwr PHA is used to turn phantom power on or off for the selected input channel Select PHA by pressing the associated Item Select Button Rotate PUSH FOR MENU SELECT change the current setting Matrix Crosspoint Xpoint Setup Screen The Matrix Setup Screen is used to apply automatic mixing and level control to the digital matrix crosspoints The settings are accomplished in re...

Страница 16: ...OTE Select the desired output channel with the item select buttons before making the following adjustments RP Gain RPG is used to view or change the rear panel gain setting for the selected output channel This setting is normally controlled by hardware connected to the programmable input ports on the rear panel of the unit i e variable resistors pots switches etc Refer to the Online Help supplied ...

Страница 17: ...e PUSH FOR MENU SELECT control to set the output source then press the PUSH FOR MENU SELECT control to accept the selection Select Mute to silence the output from the selected channel or Unmute to allow the output to pass General Settings The General Setup Screen is used to configure the DM unit as a master or as a slave M S The selected mode is stored and set as the default when the unit is initi...

Страница 18: ...he necessary changes in that screen The sec ond step is to use OK to authorize the change Finally the PUSH FOR MENU SELECT control is pressed to change the units nonvolatile memory NOTE As a safeguard the OK button must be pressed to confirm an action before pressing the PUSH FOR MENU SELECT control to initiate the action In the example the STO store active setup action has been selected with pres...

Страница 19: ...made after the preset was called Firmware Version Serial Number Active Preset Unit s placement in multiple unit chains DM s can be used as stand alone units or as part of a multiply unit chain A unit s placement as 01 of 01 indicates that it is a stand alone system If a unit is part of a multiple unit stack it s placement in that stack would be identified 02 or 03 03 of 03 etc Stacking Multiple Un...

Страница 20: ...ach number representing an Item Select Button 1 2 3 4 The factory default passcode is 1 2 3 4 from left to right Press the Item Select Buttons below the display in the sequence shown at below to enter the default pass code After the passcode is entered four symbols will appear in the upper right section of the screen to confirm the button presses Press the PRESS FOR MENU SE LECT control to accept ...

Страница 21: ...ile powering up the power Hold the buttons through the entire Boot Sequence The passcode will be reset to the factory default 1 2 3 4 NOTE Hold in buttons 2 and 5 while powering up to restore the factory default passcode 1 2 3 4 PUSH FOR MENU SELECT BACK Button 2 Button 5 Item Select Buttons Command View Screen The Command View Screen is a convenient utility to assist in verifying correct serial c...

Страница 22: ... takes effect immediately NOTE When using the RS 232 serial port in conjunc tion with the GUI software the baud rate must be set to 57600 or the GUI will not be able to connect to the device EXIT To exit the TopMenu rotate the PUSH FOR MENU SELECT control to highlight EXIT then press the con trol This exits the TopMenu and returns to the screen displaying the Model number ...

Страница 23: ... the LecNet2 Device Installer from the Installation Disk Installation with LecNet2 Device Installer Step 1 Place the LecNet2 Installation Disk into the CD ROM drive on the computer If Auto Run is enabled on that drive the installation utility will open If AutoRun is not enabled use Start Run to run auto Run exe on the drive holding the LecNet2 Installation Disk If the CD ROM drive is assigned as d...

Страница 24: ...indows XP and Vista operating systems the Found New Hardware Wizard will open when the de vice is detected It will walk you through the process of installing the LecNet2 drivers To proceed you will need the LecNet2 Installation Disk Click on the following link and follow the instructions Windows XP USB driver manual installation guide On Windows 7 operating systems the system attempts to find a dr...

Страница 25: ...1624F v1_1_12 update The dots normally used to separate the three parts of the version number are replaced with underscores in the filename for clarity Before starting make sure that the proper update file is on hand Connect the DM1624F to a computer sys tem with a USB cable Apply power to the DM1624F and start the control panel software on the computer system 1 Choose File Update from the Control...

Страница 26: ...up date file dialog opens If the file name was entered manually click Next If the browse button was clicked select the update file from the list and click Open to transfer that file name to the Path to Update File field Then click Next 5 Click Start Update to begin the firmware update The update is made in two stages an update of the DM controller firmware followed by an update of the DSP firmware...

Страница 27: ...e message to verify that the DM1624F restarts with the updated firmware version Click OK to dismiss the message At this point the process is complete and the Wizard will be ready to close Click Finish to close the Wizard At this point you can connect to the newly updated DM1624F with the control panel The updated firmware version number should appear in the status bar ...

Страница 28: ...CRLF in the examples An ellipsis represents members of an array that have been omitted from an example for the sake of brevity actpre active preset This command is used as a query to determine which memory preset is active The active preset is the last preset called from memory The data is an integer type in the range 1 to 24 The active preset value is not be assigned directly but is assigned thro...

Страница 29: ... at the crosspoint does participate in the Adaptive Proportional Gain automixing process to the extent that it s level influences the gain of other inputs assigned to the same output NOM bus However the input signal at the crosspoint does not actually get mixed into the output channel This is a global setting it affects all matrix crosspoints that have been configured to use background mix mode th...

Страница 30: ...o This command is used to run a macro an internally stored group of DM commands A single macro may be run using the command form In this case the macro is specified by using the address syntax Addresses must be in the range 1 to 128 More than one macro may be run with a single command by using the Update form In this case the data is array of integer with the variable length in the range 1 to 16 T...

Страница 31: ...y of integer of size 16 The output channel address may not be a wildcard NOTE This form was introduced with DM1624F firmware version 1 2 0 and will will not work correctly on earlier versions Examples Request Response Query inact 15 CR OK 0 CRLF Query inact CR OK 0 1 0 0 0 0 CRLF incl input clipping This command is used to determine if an audio input channel is clipping i e it is being overdriven ...

Страница 32: ... 20 repre senting the RMS audio level in dBu as measured AFTER the input preamplifier If the channel address is a wildcard then the data type is an array of integer of size 16 Examples Request Response Query inlv 1 CR OK 23 CRLF Update inlv CR OK 2 4 53 71 CRLF inmt input mute This command is used as a query to read the input channel mute status or as an update to set the status The input channel ...

Страница 33: ...dresses for the second dimension output channel must be in the range 1 to 24 or wildcarded If the input is wildcarded then the command applies to the entire column of the matrix associated with the specified output channel If the output is wildcarded then the command applies to the entire row of the matrix associated with the speci fied input channel The data type is integer in the range DM1624F M...

Страница 34: ...RLF Query xpmt 5 CR OK 0 0 1 0 CRLF Update xpmt 16 1 0 CR OK CRLF Update xpmt 15 3 1 3 99 99 3 CR OK CRLF xpmttog crosspoint mute toggle This command is used as a simple command to toggle the matrix crosspoint mute status The crosspoint is specified by using the two dimensional address syntax Addresses for the first dimension input channel must be in the range 1 to 16 Addresses for the second di m...

Страница 35: ...must be in the range 1 to 24 The data type is string with a limit of 15 characters Examples Request Response Query outlb 1 CR OK Zone 3 CRLF Update outlb 12 Gallery CR OK CRLF outlv output level This command is used as a query to read the output channel level The output channel is specified by using the address syntax Addresses must be in the range 1 to 24 The data type is integer in the range 70 ...

Страница 36: ...s syntax Addresses must be in the range 1 to 24 The data type is integer unless the channel address is a wildcard in which case the data type is an array of inte ger of size 24 The following values are allowed 0 normal operation the output channel is fed by the mixing matrix 1 the output channel is fed by a 0 dBu pink noise source 2 the output channel is fed by a 0 dBu 1 kHz tone source In the cas...

Страница 37: ...the address syntax Ad dresses must be in the range 1 to 16 The data type is integer in the range 0 to 30 representing the gain in dB The allowable upper limit of makeup gain values is dynamically determined by the threshold and ratio settings of the compressor and may be less than the absolute maximum of 30 dB If the value sent in an update request exceeds this upper limit it will be forced to the...

Страница 38: ...ied by using the address syntax Addresses must be in the range 1 to 24 The data type is integer in the range 0 to 30 representing the gain in dB The allowable upper limit of makeup gain values is dynamically determined by the threshold and ratio settings of the compressor and may be less than the absolute maximum of 30 dB If the value sent in an update request exceeds this upper limit it will be f...

Страница 39: ...resenting the time in one tenth millisecond increments Examples Request Response Query outlmatt 1 CR OK 20 CRLF Update outlmatt 15 30 CR OK CRLF outlmrel output limiter release time This command is used as a query to read the attack time or as an update to set the attack time The output channel is specified by using the address syntax Ad dresses must be in the range 1 to 24 The data type is intege...

Страница 40: ...and prgin 3 CR OK CRLF Query prgin 9 CR OK 1 CRLF Query prgin CR OK 0 0 1 0 0 0 CRLF DM1624F Programmable I O Commands prgindef programmable input definition This command may be used as a query to read a pro grammable input definition or as an update to modify the definition The programmable input is specified by using the address syntax Addresses must be in the range 1 to 22 The data type is arra...

Страница 41: ...ange 1 to 16 These identify which input channels are to be controlled by the function A sequence of zero or more integers in the range 1 to 16 These identify which input channels are to be controlled by the function A sequence of zero or more integers in the range 1 to 16 These identify which input channels are to be controlled by the function A sequence of zero or more integers in the range 1 to ...

Страница 42: ...t Response Query prgoutdef 8 CR OK 3 1 3 4 CRLF Function Monitor active preset is assigned to programmable input 8 The presets being monitored are 1 3 and 4 Query prgoutdef 1 CR OK 2 3 CRLF Function Monitor program mable input state is assigned to programmable output 1 The logical state of program mable input 3 is being monitored Function Target Values Monitor audio input activity Monitor pro gram...

Страница 43: ...en asserted or 0 meaning that it is not contacts closed when asserted the normal case If the address is wildcarded then the data type is an array of integer of size 16 In this case the value 99 may be used in an update to indicate that a particular programmable output invert state is to remain unchanged by the com mand NOTE This command available with firmware version 1 3 0 or higher only Examples...

Страница 44: ...ticular rear panel input gain is to remain unchanged by the command Examples Request Response Query rpingn 1 CR OK 3 CRLF Query rpingn CR OK 13 4 0 0 CRLF Update rpingn 2 0 CR OK CRLF Update rpingn 0 5 0 99 99 10 CR OK CRLF rpingnmin rear panel audio input gain minimum This command is used as a query to read the rear panel input gain minimum or as an update to set the gain minimum All rear panel a...

Страница 45: ...l rear panel audio output gains are con trolled by this preset value which is the value loaded when the device is powered up The data type is integer in the range 60 to 0 representing gain in dB i e the minimum attenuation possible using rear panel gain control Examples Request Response Query rpoutgnpre CR OK 0 CRLF Update rpoutgnpre 5 CR OK CRLF rpoutgnst rear panel output gain step change This c...

Страница 46: ...336 Hz 6 164 Hz 22 586 Hz 38 1383 Hz 54 2625 Hz 70 4594 Hz 86 7547 Hz 7 176 Hz 23 621 Hz 39 1441 Hz 55 2719 Hz 71 4734 Hz 87 7758 Hz 8 188 Hz 24 656 Hz 40 1500 Hz 56 2813 Hz 72 4875 Hz 88 7969 Hz 9 211 Hz 25 703 Hz 41 1570 Hz 57 2930 Hz 73 5051 Hz 89 8227 Hz 10 234 Hz 26 750 Hz 42 1641 Hz 58 3047 Hz 74 5227 Hz 90 8484 Hz 11 258 Hz 27 797 Hz 43 1711 Hz 59 3164 Hz 75 5402 Hz 91 8742 Hz 12 281 Hz 28 ...

Страница 47: ... E F a b c d e f DIGIT STR_TOK ALPHA ALPHANUM INT_TOK 1SIGN 1 DIGIT FLT_TOK 1SIGN DIGIT DIGIT note that bare is valid QSTR_TOK DQUOTE QCHAR DQUOTE CRLF CR LF OK_TOK x4F x4B uppercase string OK ERROR_TOK x45 x52 x52 x4F x52 uppercase string ERROR input query hquery update target WS CR output response WS CRLF query target WS hquery target WS WS update target WS WS argument hargument status OK_TOK ER...

Страница 48: ...nt to know that when a macro is run the response messages normally returned when the com mands are executed individually are discarded This means that ill formed or unsuccessful commands fail silently as the error message is discarded Queries commands which request information from the DM make no sense within a macro Macros can be chained if necessary meaning that one macro can call another macro ...

Страница 49: ...ucting to ground When the output is inactive the contact is open not conducting to ground An important application of the rear panel control inter face is to manage what is called the rear panel gain for input and output audio channels This is an additional gain value that is added to the main gain value for a channel to give the total gain applied Rear panel gain is limited to the range 61dB to 0...

Страница 50: ......

Страница 51: ...osonics Inc will pay for the cost of returning your equipment to you This warranty applies only to items returned to Lectrosonics Inc or an authorized dealer shipping costs prepaid within one year from the date of purchase This Limited Warranty is governed by the laws of the State of New Mexico It states the entire liablility of Lectrosonics Inc and the entire remedy of the purchaser for any breac...

Отзывы: