a) ORP Controller - Install part # 993 per the instructions provided.
NOTE: This is a dry contact input, DO NOT ENERGIZE THIS INPUT! DAMAGE TO THE CONTROL
PANEL WILL OCCUR AND THE WARRANTY WILL BE VOIDED. When an ORP controller is
interfaced to the LIBERTO unit, your Output Control Dial should be set on 100%.
b) Power Fuse -On the Control Panel circuit board is a 2 amp power fuse labeled FS1 for the
110V unit, and a 1 amp fuse for the 220V unit. This fuse protects the Control Panel and cell
from voltage spikes. If no lights display, inspection and possible replacement of this fuse may
be necessary. The output control dial and cover must be removed from the unit to access this
fuse.
UNION
LIBERTO
CONTROL
PANEL
FLOW
DETECTOR
R e q u i r e d S a l t L e v e l
2 8 0 0 - 3 2 0 0 p p m
CHECK MONTHLY
Electronic Component Location CP3 and CP5
Control Panel Models CP3 and CP5
LIBERTO
Section 3 b
Section 3 b