Lec BC6097K Скачать руководство пользователя страница 12

            www.lec-commercial.co.uk  

      12 

 

Controller Operation 

 
 

View or Change the Current Set Temperature 

 

Function 

Press 

Hold button(s) 

down for 

Result 

To view/set 
temperature 

 

 

1 second 

Displays current set 
temperature 

Followed by 

 or 

 

Until desired 

temperature is 
reached 

Modifies and saves 

set temperature 

Followed by 

 

1 second 

Exits the 

adjustment and 
displays internal 

temperature 

Note:

 If no more buttons are pressed within 6 seconds, the interior temperature will be displayed. 

 

 

Performing a Manual Defrost cycle 

 

Function 

Press 

Hold button(s) 

down for 

Result 

Manual start / stop 

Defrost 

 

6 seconds 

Starts or stops 

defrost. Defrost LED 

illuminates when 

defrost is in 
progress. 

Note:

 If no more buttons are pressed within 6 seconds, the interior temperature will be displayed. 

 

 

 
IMPORTANT

: Ensure you Clean and dry thoroughly before switching back “ON” after 

performing a manual defrost cycle. 

 
 

LED indication symbols

 

 

 

 

 

 

Содержание BC6097K

Страница 1: ...USER MANUAL EfficienC Bottle Cooler Range Applicable Models BC6097K BC6097ST BC9097K BC9097ST...

Страница 2: ...s page 9 Internal Light page 10 Doors page 10 Shelves page 10 Adjusting the Feet page 10 Controller Overview page 11 Controller Operation page 12 Energy Saving Tips page 13 Storage page 13 Disposal pa...

Страница 3: ...ct our After Sales team IMPORTANT The Model Number Product Code and Serial Number can all be found on the data plate located on the interior of your appliance Model Number Product Code Serial Number D...

Страница 4: ...d stand for 2 hours to allow the refrigerant to settle Warranty How to activate your Warranty This Lec Commercial ECA approved bottle cooler comes with a 2 years Parts and Labour warranty from the dat...

Страница 5: ...uld be placed on a hard flat surface for ventilation The feet must be adjusted so that the cabinet stands firm and level with a slight tilt from front to back to prevent any defrost water dripping fro...

Страница 6: ...ngerous WARNING THIS APPLIANCE MUST BE EARTHED If a non rewirable plug or a rewirable 13 Amp BS 1363 plug is used it must be fitted with a 13 Amp ASTA approved BS 1362 fuse If any other plug is used p...

Страница 7: ...safety at risk and will invalidate your warranty DO NOT store explosive substances such as aerosol cans with a flammable propellant in this appliance This appliance is not intended for use by persons...

Страница 8: ...lead of your appliance into a suitable earthed socket and switch on IMPORTANT When using the bottle cooler for the first time it is essential that you allow it to run for 24 hours before filling to en...

Страница 9: ...C Stainless Steel 1 Hinged 106 BC9097K 900 x 500 x 900 R600a 2 C to 10 C Black 2 Hinged 180 BC9097ST 900 x 500 x 900 R600a 2 C to 10 C Stainless Steel 2 Hinged 180 Note Additional or replacement parts...

Страница 10: ...o operate less efficiently Shelves The Bottle Cooler is fitted with adjustable shelves that can be moved to suit your storage needs The support clips right are removed by pressing them together and ti...

Страница 11: ...Controller Overview Applies to ALL models 1 2 3 4 5 6 1 Maximum Temperature Up button 2 Defrost button 3 Interior Light On Off switch 4 Minimum Temperature Down button 5 Current Temperature Display 6...

Страница 12: ...ays internal temperature Note If no more buttons are pressed within 6 seconds the interior temperature will be displayed Performing a Manual Defrost cycle Function Press Hold button s down for Result...

Страница 13: ...premises is closed Storage If your appliance is to remain unused for a period of time e g during refurbishment work it is advised that the appliance is unplugged from the power supply Ensure that the...

Страница 14: ...ystem that requires no special operations on the part of the user The on off cooling cycles of the appliance are specifically designed to allow for defrost during normal operation Manual defrost Instr...

Страница 15: ...nd wipe with a soft cloth ensuring that they are dry before replacing Detergents containing abrasives or acids are not suitable for cleaning and must NOT be used When all cleaning has been completed r...

Страница 16: ...e or alternatively contact our After Sales support team on 0844 815 3755 Note You will need to have the date of purchase the product code the model number and serial number found on the data plate lab...

Страница 17: ...it from the bottom flange towards the rear of the cabinet and then pull it downwards 3 The light bulb is rotated turn to align the connector pins and then moved carefully to free it from its sockets...

Страница 18: ...cm at each side 6cm at the rear and 2 5cm at the top 2 Check that the air ventilation at the bottom of the cabinet is unobstructed as this allows air to circulate around the cabinet 3 Ensure the appli...

Страница 19: ...l bottle coolers have a temperature range of 2 C to 10 C You can easily change the temperature by following the instructions on page 12 5 How do I operate the light inside the unit Simply flick the re...

Страница 20: ...arts email info gdpa co uk tel 0844 815 3755 Opt 3 fax 0844 248 4123 Marketing Enquiries email marketing gdpa co uk Opt 5 tel 0844 248 4274 For all International Non UK Enquiries email info gdpa co uk...

Отзывы: