2F-85 & 2F-140 - Instruction Manual
Step 2: Read Gripper status until the activation is completed
Request is: 09 04 07 D0 00 01 30 0F
Bits
Description
09
SlaveID
04
Function Code 04 (Read Input Registers)
07D0
Address of the first requested register
0001
Number of registers requested (1)
300F
Cyclic Redundancy Check (CRC)
Response (if the activation IS NOT completed): 09 04 02 11 00 54 A1
Bits
Description
09
SlaveID
04
Function Code 04 (Read Input Registers)
02
Number of data bytes to follow (1 register x 2 bytes/register = 2 bytes)
1100
Content of register 07D0 (GRIPPER STATUS = 0x11, RESERVED = 0x00): gACT = 1 for "Gripper Activation", gSTA = 1 for
"Activation in progress"
54A1
Cyclic Redundancy Check (CRC)
Response (if the activation IS completed): 09 04 02 31 00 4D 61
Bits
Description
09
SlaveID
04
Function Code 04 (Read Input Registers)
02
Number of data bytes to follow (1 register x 2 bytes/register = 2 bytes)
3100
Content of register 07D0 (GRIPPER STATUS = 0x31, RESERVED = 0x00): gACT = 1 for "Gripper Activation", gSTA = 3 for
"Activation is completed"
4D61
Cyclic Redundancy Check (CRC)
74
Содержание Robotiq 2F-140
Страница 22: ...2F 85 2F 140 Instruction Manual Fig 3 1 Installing the gripper on the robot wrist for CB Series 22...
Страница 23: ...2F 85 2F 140 Instruction Manual Fig 3 2 Installing the gripper onto the robot wrist for e Series 23...
Страница 48: ...2F 85 2F 140 Instruction Manual Fig 4 1 2 Finger control logic overview 48...
Страница 117: ...2F 85 2F 140 Instruction Manual Fig 5 2 2F 85 dimensions closed Fig 5 3 General dimension of 2F 140 opened...