Chapter 7 Alarm and Processing
7.1 Alarm List
Protection function is activated when an error occurs, the drive will stop the rotation of servo motor, and the
configuration software will automatically display the corresponding fault error code in the alarm display
window. The history of the error can be viewed on alarm window from the configuration software also.
Table 7.1 Error Code List
603F(hex)
Error code
1001(hex)
Error register
Configuration
software
Content
2211
2
0E0
Over-current
2212
2
0E1
Over-current of intelligent power module (IPM)
3150
4
0A0
Current detection circuit error
3151
4
0A1
Current detection circuit error
3153
4
0A3
Power line
(
U
、
V
、
W
)
break
3201
4
0A5
DC bus circuit error
3211
4
0C0
DC bus over-voltage
3221
4
0D0
DC bus under-voltage
4210
8
0F0
Drive over-heat
5530
80
240
CRC verification error when EEPROM parameter saved
5531
80
241
I
2
C Communication status error
5532
80
242
Read/write history alarm error
5533
80
243
Read/write diagnostic data error
5534
80
244
Read/write bus communication parameters error
5535
80
245
Read/write 402 parameters error
6321
80
210
input interface allocation error
6322
80
211
input interface function set error
6323
80
212
output interface function set error
6329
80
090
FPGA communication error
7122
80
5F0
Motor code error
7321
80
150
Encoder wiring error