User Manual of iSV2-CAN Servo
www.leadshine.com
104
The input signal aren’t
assigned with any functions.
Check the value of Pr_410,
Pr_411, Pr_412, Pr_413, if it is
proper or not
Assure the value of Pr_410,
Pr_411,Pr_412,Pr_413 set
correctly
Error
code
Main
Extra
Display:
“
”
Content
:
CRC verification error when EEPROM parameter is saved
Cause
Confirmation
Solution
Vdc/GND under-voltage
Check the voltage of Vdc/GND
terminal
Make sure voltage of Vdc/GND in
proper range
Drive is damaged
save the parameters for several
times
replace the drive with a new one
The setting of drive maybe
default setting which isn’t
suitable for motor .
Check the setting of drive if it is
suitable for your motor
Download the suitable project file to
drive for motor
Error
code
Main
Extra
Display:
“
”
Content
:
positive negative over-travel input valid
Cause
Confirmation
Solution
positive /negative over-travelling
input signal has been conducted
Check the state of positive
negative over-travel input signal
/
Error
code
Main Extra
Display:
“
”
Content:
Analog value 1 input error limit
Cause
Confirmation
Solution
Analog value 1
input error limit
Analog value 1 input error limit
Error
code
Main
Extra
Display:
“
”
Content
: forced alarm input valid
Cause
Confirmation
Solution
Forced-alarm input signal
has been conducted
Check forced-alarm input signal Assure input signal wiring correctly
Error
code
Main
Extra
Display:
“
”
Content:
Motor code error
Cause
Confirmation
Solution
Motor code error
Motor code error
Set Pr7.15 correctly