User Manual for ELD5 Servo
(V1.00)
www.leadshine.com
78
1. Analog torque command input
Table 7.21 Parameter Setup of Analog Torque Command Input
No
Parameter Name
Setup Method
1
PA_318
Torque command direction selection
Please refer to chapter 4
2
PA_319
Torque command input gain
3
PA_320
Torque command input reversal
4
PA_422
Analog input offset setup
5
PA_423
Analog input filter
2. Speed limit function
The speed limit is one of protective functions used during torque control.
This function regulates the motor speed so that it doesn’t exceed the speed limit while the torque is controlled.
Table 7.22 Parameter Setup of Speed Limit Function
No
Parameter
Name
Setup method
1
PA_321
Speed limit value 1
Please refer to chapter 4
2
PA_315
Zero-clamp function selection
3
PA_302
Speed command input gain
4
PA_422
Analog input offset setup
5
PA_423
Analog input filter
3. SI/SO function set
For details of SI input function, refer to PA_400 – PA409.
For details of SO output function, refer to PA_410 – PA415.