User Manual for ELD5 Servo
(V1.00)
www.leadshine.com
33
4.2.3
【
Class 2
】
Vibration Suppression
time-delayed.
Pr1.36* pulse digital filter of encoder
feedback setup
Range
unit
default
Related
control mode
0 -10000
0.1ms
33
P
Do filtering for pulse of encoder feedback, eliminate the interference of the narrow pulse, over-large
setup will influence the performance of motor in large speed, and influence the control performance
of motor causing by large time-delayed.
Pr2.01 1st notch frequency
Range
unit
default
Related
control mode
50 -2000
HZ
2000
P
S T
Set the center frequency of the 1st
notch filter
Notice: the notch filter function will be invalidated by setting up this parameter to “2000”.
Pr2.02 1st notch width selection
Range
unit
default
Related
control mode
0 -20
-
2
P
S T
Set the width of notch at the center frequency of the 1st notch filter.
Notice: Higher the setup, larger the notch width you can obtain. Use with default setup in normal
operation.
Pr2.03 1st notch depth selection
Range
unit
default
Related
control mode
0 -99
-
0
P
S T
Set the depth of notch at the center frequency of the 1st notch filter.
Notice: Higher the setup, shallower the notch depth and smaller the phase delay you can obtain.
Pr2.04 2nd notch frequency
Range
unit
default
Related
control mode
50 -2000
HZ
2000
P
S T
Set the center frequency of the 2nd
notch filter
Notice: the notch filter function will be invalidated by setting up this parameter to “2000”.
Pr2.05 2nd notch width selection
Range
unit
default
Related
control mode
0 -20
-
2
P
S T
Set the width of notch at the center frequency of the 2nd notch filter.
Notice: Higher the setup, larger the notch width you can obtain. Use with default setup in normal
operation.
Pr2.06 2nd notch depth selection
Range
unit
default
Related
control mode
0 -99
-
0
P
S T
Set the depth of notch at the center frequency of the 2nd notch filter.
Notice: Higher the setup, shallower the notch depth and smaller the phase delay you can obtain.
Pr2.22 positional command smoothing
filter
Range
unit
default
Related
control mode
0 -32767
0.1ms
0
P
Set up the time constant of the1st
delay filter in response to the positional command.