3
2. SPECIFICATIONS
2.1
General
This instrument is designed to be connected to the Ethernet port on the rear panel of the LV
7390 and used to remotely control the LV 7390. It enables remote control using panel
controls similar to those of the LV 7390.
2.2
Features
● Control via Ethernet
This instrument enables long-distance remote control using Ethernet.
● Similar Controls Synchronized to the LV 7390
This instrument provides controls similar to the LV 7390 panel. It can be used as though
you are using the LV 7390 panel. Changes to the LV 7390 controls are immediately
reflected to this instrument.
● Multiple Connections (Up to 8 units)
The LV 7290 can connect to multiple LV 7390s and control them exclusively.
* The TELNET features of the LV 7290 and LV 7390 cannot be used simultaneously.
2.3
Specifications
2.3.1
Control
Compatible Model
LV 7390
(firmware version 2.0 or later)
Connection System
Telnet communication over Ethernet
(DHCP is not supported)
Control a single LV 7390 from multiple LV 7290s
simultaneously
Control up to eight LV 7390s exclusively from a single LV
7290
Operation Description
LV 7390 control through control code transmission
Panel LED indication by receiving LED data from the LV
7390
Connection Configuration
Settings
IP Address
Subnet Mask
Default Gateway
IP Address of the connection destination 1 to 8
Configuration Method
Configure from the PC app (included)
Configure from the connected LV 7390