2. SPECIFICATIONS
28
2.3.23
Jitter Display (SER02)
Display
Displays the jitter component of an SDI signal
3G, HD, SD
Displays channel A, B, C, or D, whichever is selected
HD (DL)
Displays link A or B, whichever is selected
3G (DL)
Displays link 1 or 2, whichever is selected
3G (QL), HD (QL)
Displays link 1, 2, 3, or 4, whichever is selected
Waveform Display Color
7 colors to choose from
Scale Display Color
7 colors to choose from
Method
Phase detection method
Gain
×8, ×2, ×1
Measurement Range
×8
0.00 to 1.20 UI
×2
1.20 to 4.80 UI
×1
4.80 to 9.60 UI
Frequency Response
SD
600 kHz or more (with 0.2 UI input)
HD
2 MHz or more (with 0.2 UI input)
3G
2 MHz or more (with 0.3 UI input)
Time Axis
1 H, 2 H, 1 V, 2 V (*1)
Time Axis Accuracy
±3 %
Jitter Filter
10 Hz
HPF 10 Hz
100 Hz
HPF 100 Hz
1 kHz
HPF 1 kHz
100 kHz
HPF 100 kHz
Timing HPF
10
Hz
Alignment
3G, HD
HPF 100 kHz
SD HPF
1
kHz
Cursor Measurement
Jitter value measurement through the use of cursors
Automatic Measurement Display Feature
Displays the jitter value in seconds (sec) and unit
intervals (UI)
Automatic Measurement Items
Timing jitter, current jitter
Accuracy
Input jitter frequency: 1 kHz. Filter setting: 10 Hz, within
measurement range
0 UI < automatic measurement value
±10 % + 0.05 UI
1 UI < automatic measurement value
±10 %
*1
2V display is not possible when the input signal is progressive except for 60/59.94/50P of HD (DL).
USO
RESTRITO
Содержание LV 5490
Страница 2: ...TABLE OF CONTENTS USO RESTRITO...
Страница 3: ...USO RESTRITO...
Страница 4: ...USO RESTRITO...
Страница 5: ...USO RESTRITO...
Страница 132: ...10 MENU TREE 123 10 2 INPUT Menu USO RESTRITO...
Страница 133: ...10 MENU TREE 124 10 3 SYS Menu USO RESTRITO...
Страница 134: ...10 MENU TREE 125 10 4 CAP Menu USO RESTRITO...
Страница 135: ...10 MENU TREE 126 10 5 PSET Menu USO RESTRITO...
Страница 139: ...USO RESTRITO...