3. 12G OPTION MENU
24
3.3.2
Selecting the Fixed Pattern
To select the fixed pattern, follow the procedure below.
4.SDI1 COLOR BAR
►*100%
Procedure
12G OPTION → SDI1 → PATTERN → PATTERN SELECT → FIX PATTERN
Parameter
COLOR BAR 100% (default value) / 75% / MULTI 100% / MULTI 75% / MULTI (+I) /
SMPTE / EBU / BBC / ARIB STD-B66-2
MONITOR FLAT FIELD 100% / FLAT FIELD 0% / RED FIELD 100% /
GREEN FILED 100% / BLUE FIELD 100%
SDI
CHECK FIELD
The selectable patterns depend on the SDI format as shown below.
Pattern
SDI format
Other than those
on the right
720x487:SD 720x576:SD
3840x2160
4096x2160
COLOR
BAR
100%
Y
Y
Y
Y
Y
75%
Y
Y
N
Y
Y
MULTI 100%
Y
N
N
Y
Y
MULTI 75%
Y
N
N
Y
Y
MULTI (+I)
Y
N
N
Y
Y
SMPTE
N
Y
N
N
N
EBU
N
N
Y
N
N
BBC
N
N
Y
N
N
ARIB STD-B66-2
N
N
N
Y
L*
MONITOR
-
Y
Y
Y
Y
Y
SDI
-
Y
Y
Y
N
N
(Y: Can be selected, N: Cannot be selected, L: Can be selected but a portion of the area will not display anything)
* Because ARIB STD-B66-2 is a fixed pattern that is 3840x2160 in size, 256 dots on the right side will not display
anything if displayed in the 4096x2160 size.