background image

lemaitrefx.com

Page 1

Introduction

Page 2

Warning

Page 3

Safety Precautions

Page 4

Technical Specifications

Page 5

Operating Procedure

Page 6

Remote Handset Operations

Page 6

DMX Control Procedure

Page 7

Remote Handset Image

Page 7

DMX Control Image

Page 8

Stage Fogger DMX Tube  Change Procedure Images

Page 9

Stage Fogger DMX Tube Change Procedure

Page 11

Recommended Fluids

Page 12

Warranty

Please Read Carefully Before Operating

Table of Contents

Содержание Stage Fogger DMX

Страница 1: ...lemaitrefx com Stage Fogger DMX Operations Manual V 06 29 05 ...

Страница 2: ... Procedure Page 6 Remote Handset Operations Page 6 DMX Control Procedure Page 7 Remote Handset Image Page 7 DMX Control Image Page 8 Stage Fogger DMX Tube Change Procedure Images Page 9 Stage Fogger DMX Tube Change Procedure Page 11 Recommended Fluids Page 12 Warranty Please Read Carefully Before Operating Table of Contents ...

Страница 3: ...ter Status temperature Water Base Fog technology is achieved by pumping a Glycol Water mixture through a Heat exchanger The heat exchanger has been heated to the point where at the fog fluid mixture will vaporize The fluids own vaporization forces the hot mixture out of the output nozzle where when it mixes with the ambient air it forms an opaque aerosol fog The fog is made up of tiny droplets of ...

Страница 4: ...een disconnected from the machine Important Safety Instructions Persons suffering from asthma or allergenic sensitivity may experience irritation discomfort or allergic symptoms when exposed to fog effects Important Safety Instructions Ensure that this unit is grounded at all times Failure to do so may result in serious injury Important Safety Instructions Never use alternative fluids Toxicity fre...

Страница 5: ...e Maitre Special Effects 6 Do not continue to produce Fog output in an enclosed area when visibility is reduced below 50cm 7 Avoid direct Fog output continuously at persons structure or objects within close prox imity of the discharge nozzle 8 Ensure that adequate exhausting arrangements are available in the event of an emergency 9 Do not place hands or exposed skin within the first 50cm of the di...

Страница 6: ...er Base Fog generating system Size Height 10 3 4 27 3 cm Width 10 3 8 26 3 cm Length 25 1 2 63 5 cm Net Weight 13 6 Kg 30 lbs Weight With Fluid 17 7 Kg 39 lbs Power Rating 110 Volt A C 50 60 Hz 13 Amps 240 Volt A C 50 60 Hz 6 5 Amps Included Full Timer Remote RCT Replacement Kit On Board DMX ...

Страница 7: ... will begin flashing quickly when the fog machine is ready to operate Fog is available at this point but full fog output will not be available After approximately 9 minutes the indicator will be solid when the fog machine has fully heated and is ready for use at full fog output if required 6 It may now be necessary to prime fluid into the system to expel any air that might be present The Variflow ...

Страница 8: ...at the unit is ready to fog at full output No Illumination Problem Check Remote Handset connection on the rear panel of Stage Fogger DMX If this fails to correct the problem contact your local Le Maitre dealer The Stage Fogger DMX comes equipped with onboard DMX Control as a standard feature Figure 2 Page 7 1 Plug in the 5 pin DMX cable into the DMX IN connector located on the rear of the Stage Fo...

Страница 9: ...lemaitrefx com 7 Remote Handset Image Duration Control Interval Control Vari Flow Control Fog On Off Switch Handset Indicator Figure 1 External Connector and DMX Operation Figure 2 ...

Страница 10: ...lemaitrefx com 8 Stage Fogger DMX Tube Change Images Figure 4 Figure 5 Figure 6 Two Screws Protective Shield ...

Страница 11: ...he 7 16 brass nut at the pump This line may be under significant pressure if the tube was plugged 5 Be careful not to damage any exposed wiring Remove the upper steel plate by loosen ing the five nuts with a 1 2 socket Gently lift the plate back out of the way leaving the high temperature switch undisturbed 6 Lift the aluminum plate up cautiously to avoid damage to the Thermal sensor Figure 6 Page...

Страница 12: ... tube 8 Thread the five nuts and lock washers on finger tight Check alignment of the layers Tighten the center bolt down snug with a 1 2 socket Repeat with the other four bolts Move to the center bolt and pull tighter by a quarter turn This will give 5 7 foot pounds of torque Repeat this on the remaining four bolts 9 Install top insulation and plug in fog machine and allow to heat up fully Run fog...

Страница 13: ...tes at about twice the rate of the Quick Dissipating Molecular Fog Fluid The Molecular Fluid was originally designed for use in the LSG and LSX however many other applications were found very quickly It is clean white thick fog practically odourless and dissipates as it begins to warm Maxi Fog Fluid Maxi Fog Fluid was developed for our high volume users requiring an excellent balance of price and ...

Страница 14: ...freight prepaid to our facility and we will prepay freight back to your facility after repair by the most economical means available Should you require the item express returned then you are responsible for any difference in freight cost Return Policy Return of any product must be done within 30 days of purchase The package must be returned freight prepaid and the RA num ber clearly marked on the ...