Flame Height
As standard, the Chameleon is
not
fitted with a height adjustment valve. Units can be made to
order with adjustable height, or a height adjustment valve can be fitted to an existing unit.
Please contact the manufacturer for further information.
If fitted, the height adjustment valve wheel is located on the right hand underside of the machine
(viewed from the rear), the perimeter of which can be felt protruding from case.
Anticlockwise
rotation opens this valve for
maximum flame
height (hand movement from rear to front of
machine).
Clockwise
rotation closes this valve for
minimum flame
height (hand movement
from front to rear of machine)
It should be noted that if the canister solenoid is left open and only the Flame solenoid used for
control, then the gas storage between the solenoids will create a flame ball or higher initial flame
before the flame reduces to the set height.
To have a consistently lower flame height, control both solenoids simultaneously, so that the
gas storage is not replenished.
To create a flame ball, allow the canister solenoid to be open first, and then operate the flame
solenoid.
The Control Panel
The control panel provides the following functions:
A SELECT button allows the
H
ot surface igniter,
F
lame, and
C
anister DMX addresses to be
selected individually as well as setting the Chameleon into the DMX receive mode. Continual
presses of this button will cycle through these events.
UP and DOWN buttons allow each address to be adjusted to suit the user. These addresses
are not allowed to be equal or more than 256 steps apart. A warning will be given on the display
to reset these values should this occur. Whilst in the mode of setting addresses the
STORE/VIEW button will place these values in memory.
When the DMX mode is selected for receiving data, the STORE/VIEW button will allow the
received DMX data value to be viewed for each channel. ( 0 to 99%) or scrolled through.
H = Hot surface igniter. F = Flame. C = Canister. Pressed a fourth time it will autoscroll.
When the DMX mode is selected, and there is no DMX data the display will read doF. (DMX off)
With no DMX connection a special function STORE/VIEW + UP button will set a value in
memory which relates to the time required for the Hot surface igniter to reach the correct
working temperature and allow the Flame solenoids to function.
The UP/DOWN buttons will vary the set value from 0 to 254. To exit from this feature, press the
SELECT button.
Typically a value of 50 will equal a 5 second delay. A value of 100 will equal 11 seconds and a
value of 200 will equal around 35 seconds. Each time this value is changed by the button
presses, it will be stored in memory.
This value may need to be changed if the Hot Surface igniter is replaced, or special user
circumstances require it.
Changing this value and allowing a shorter time before Flaming is allowed may well create
unsafe or hazardous conditions, allowing unburned fluid to be ejected. The onus of responsible
will lie with user.