Conditions of use 

           

The Chameleon is only suitable for indoor use, or situations that meet the 

same environmental conditions. 

The machine must only be used vertically, secured in position, protected 
from unauthorised interference, impact forces and vibration. 
Any  installation  or  re  positioning  should  only  be  performed  when  the 
machine  is  cool,  disconnected  from  the  mains  supply  and  all  data 
communication. 

           

Safety distances must be given a priority when using the Chameleon. 

This not only includes those in the performance area, but to surrounding 
flammable objects and the base area upon which the Chameleon is sited. 
Full risk assessments must be made before use, and all relevant 
emergency failure procedures must be immediately available. i.e. qualified 
personnel, fire extinguishers and medical aid. 
All operations should have undergone preliminary tests and rehearsal. 
Should any conditions change that would indicate an unsafe operation an 
emergency shut down should be instigated. 
E-stop control should always be included in any installation format. 

 

An absolute minimum guidance is a safety radius of 2m. 
An absolute minimum guidance is a height safety distance of 8m. 
These distances should not less than that dictated by risk assessment. 
These distances will not apply to instances where drafts or airflow will 
cause the calculated safety distances to be greater. 

       

The  use  of  an  electronic  gas  sensor,  which  should  be  part  of  standard 
equipment used by qualified personnel, is recommended for checking the 
integrity of the Chameleon as a standard safety procedure. 

           

No canister, fuel supply or alternative gas / fluids should be used with the 

Chameleon unless specifically approved by the manufacturer. 

No modifications, alterations or service is permitted unless specifically 
approved by the manufacturer. 

Содержание Chameleon

Страница 1: ...ld there be any doubt as to the safety of operation of the machine under any circumstances the machine should be taken out of service immediately The Chameleon must not be used in confined spaces under any conditions of rain snow or precipitation of any fluids or moving air which will cause the flame to divert from a vertical path Warning Failure to observe correct operating procedures may lead to...

Страница 2: ...All operations should have undergone preliminary tests and rehearsal Should any conditions change that would indicate an unsafe operation an emergency shut down should be instigated E stop control should always be included in any installation format An absolute minimum guidance is a safety radius of 2m An absolute minimum guidance is a height safety distance of 8m These distances should not less t...

Страница 3: ... assessment Usage Compliance with Authority requirements Effect demonstration Approval Safety distances Fire prevention Fire procedures Emergency fail equipment and procedures These and local legislation must all be taken into account before the Chameleon can be used It must be stated that under no conditions should the Chameleon be modified or used in an exposed condition that might lead to injur...

Страница 4: ...ntial dangers involved in using a flame machine of this nature In every instance of use the user should be confident that all possible scenarios involving safety issues are fully and confidently covered Regularly test the operation of both solenoid valves Recommended procedure is outlined below it requires program type 2 PrG2 see page 10 The test should be given the same safety precautions as norm...

Страница 5: ...me solenoids and an external mains power output socket Channel is considered active when its value is raised to more than 50 Use of flash button is advised for the firing channel The Hot surface igniter will take approximately 10 seconds to reach the correct operating temperature after which flame operation will be allowed A flashing display indicates that this heating process is taking place The ...

Страница 6: ...reset in order to resume operation The Chameleon is supplied set to PrG 2 mode whereby separate DMX channels control the two solenoids Hsi channel1 Nozzle solenoid channel2 Canister Beacon output channel3 Please refer to the Program Type information at the end of this document if the alternate mode is required ...

Страница 7: ...as hot as the flame itself so the height adjustment must also take this into consideration Under no circumstances should any foreign body or chemical be introduced into the flame itself this is potentially very dangerous There are no user serviceable parts within the Chameleon system and any faults should be dealt with by a qualified engineer or the unit should be returned to the manufacture forre...

Страница 8: ...smitting before the unit is switched on The Hot surface igniter should be activated until the control display stops flashing then the flame channel s activated If fluid remains in the system this will be burnt off When viewing the Hot surface igniter stay at least 3 metres from the machine After all fluid has been burnt off solenoids can be heard to click on flame activation Attach a mains driven ...

Страница 9: ... button will cycle through these events UP and DOWN buttons allow each address to be adjusted to suit the user These addresses are not allowed to be equal or more than 256 steps apart A warning will be given on the display to reset these values should this occur Whilst in the mode of setting addresses the STORE VIEW button will place these values in memory When the DMX mode is selected for receivi...

Страница 10: ...d Pressing Up and Down then toggles the Tilt Switch on or off Purge Setting This allows solenoid action with no Hot surface igniter action Where gas can be issued safely this mode allows the system to be purged of gas The Hsi will be disabled to prevent flames To access this mode reduce the above delay setting to below 10 Remember to return the delay setting value to its original value and store i...

Страница 11: ...above purge mode Hardwiring of the solenoids to the PCB connectors must be altered depending on what program is selected Wiring Nozzle Solenoid to Sol Fl connection on the PCB Canister Solenoid and Beacon wires to the Beacon connection on the PCB Service Note It is possible that under certain conditions of use a fine layer of evaporated coloured salts may build up on the one way valve discs within...

Страница 12: ...te although the machine should not be used below 5C if it is switched on when extremely cold there is a chance that the mains fuse may break due to large current peaks taken by the Hot Surface igniter under such conditions Replace the fuse with the same rating and wait until the machine has returned to normal working temperature conditions Contact Details UK Le Maitre Ltd 6 Forval Close Wandle Way...

Страница 13: ...13 Control Panel Layout ...

Отзывы: