DigitalBooster DB-4 – Manual
-
4
-
Please connect a plug of the 5-poles boosterbus cable onto the command station or to
the previous booster. The connection of the plug is correct at the
Control Unit
,
Intellibox
,
TWIN-CENTER
,
Märklin Booster 6017
,
Power 2
and
Power 3
if the direction
of the
cable shows to the bottom
. For the
Märklin Booster 6015
is the correct position
of the
Boosterbus-Cable
showing
to the top
.
The second plug of the boosterbus cable has to be connected at the
DigitalBooster DB-
4
to the
pin bar ST1
with the
marking “
IN
”.
Please attend that the
white single wire
of the 5-poles cable
corresponds
to the
white
marking
at the
pin bar ST1
.
The plug position of the 5-poles boosterbus cable is correct on the
DigitalBooster
DB-4
if the twisted cable has a direction away from the booster.
If a following booster shall be connected with a 5-poles boosterbus cable to the
DigitalBooster DB-4
this has to be done via the
pin bar ST2
(“OUT”)
.
BU
1
+
S1
D
CC
M
M
JP
1
JP
2
JP
3
JP
4
O
FF
O
N
Au
to
G
o
R
ai
lC
om
S
ho
rt
R
ep
o
rt
red
bro
wn
LE
D1
LE
D2
GO
ST
OP
+
Litt
fin
ski
D
ate
nTe
ch
nik
(L
DT
)
KL
1
K
J
4,
5
2,
5
JP
5
OUT
IN
ST1
ST2
Rev. 1.4
DB-4
B
U
3
B
U
2
C
D E
STOP/GO
KL2
KL4
KL3
Feedback
A
T
2,5 / 4,5 Ampere Booster für die Digitalformate Märklin-
Motorola, mfx®, M4 und DCC.
2,5 / 4,5 ampere booster for Märklin-Motorola, mfx®, M4
and DCC.
DB-4
DigitalBooster
Multi-Digital
Littfinski DatenTechnik (LDT)
www.ldt-infocenter.com
Digital-Profi werden!
braun
brown
J
rot
red
K
Vom DB-4-PowerSupply 2
From DB-4-PowerSupply 2
Gleisbereich 2
Track section 2
weiss
white
BU
1
+
S1
D
CC
M
M
JP
1
JP
2
JP
3
JP
4
O
FF
O
N
Au
to
G
o
R
ai
lC
om
S
ho
rt
R
ep
o
rt
re
d
br
ow
n
LE
D1
LE
D2
GO
ST
OP
+
Litt
fin
sk
i D
ate
nTe
ch
nik
(L
DT
)
KL
1
K
J
4,
5
2,
5
JP
5
OUT
IN
ST1
ST2
Rev. 1.4
DB-4
B
U
3
B
U
2
C
D E
STOP/GO
KL2
KL4
KL3
Feedback
A
T
2,5 / 4,5 Ampere Booster für die Digitalformate Märklin-
Motorola, mfx®, M4 und DCC.
2,5 / 4,5 ampere booster for Märklin-Motorola, mfx®, M4
and DCC.
DB-4
DigitalBooster
Multi-Digital
Littfinski DatenTechnik (LDT)
www.ldt-infocenter.com
Digital-Profi werden!
braun
brown
J
rot
red
K
Vom DB-4-PowerSupply 1
From DB-4-PowerSupply 1
Gleisbereich 1
Track section 1
weiss
white
Bestellbezeichnung /
Order code: Kabel Booster 1m
Von Digitalzentrale
From command station
Zu weiteren Boostern
To further boosters
page_1117
DigitalBooster DB-4 connection to the command station and between each other via the 5-poles
boosterbus.
2.2. DB-4 connection via the CDE-Boosterbus:
If your
Command Station
contains a
CDE-Boosterbus
the connection to the
DigitalBoosters DB-4
can be realized with three cables. Connect the
connection wires
C
,
D
and
E
of the
Command Station
with the
clamps
C
,
D
and
E
of the following
DigitalBooster DB-4
.