background image

DigitalBooster DB-4 – Manual

 

 

 

 

 

 

 

10

 -

 

 

5. Booster in Operation:

 

 

All  jumpers 

of  the

  DB-4  are  set  ex-factory

.  The 

DigitalBooster

 

DB-4

  can  be 

used

 

immediately

 at the 

supplied condition

. The 

factory setting

 is recommended for the 

first implementation

 of the unit. 

For selecting 

different operation modes

 after the first implementation please attend to 

the chapter “

Adjusting Operation Modes with Jumpers

”. 

 
After switching-on the model railway layout at first the 

red LED

 of the 

DigitalBooster 

DB-4

 will 

glow

. If the 

red and the green LED

 will 

alternate flash

 the 

supply voltage

 

has 

not been set

 correctly 

at the range of 15 to 24 Volt

. Please 

check

 and correct the 

voltage setting

 at the 

DB-4-PowerSupply

 

If the

 red LED

 of the 

DigitalBooster DB-4

 will

 glow constantly 

after

 switching-on 

the 

layout the 

DB-4

 is in operation mode and can be switched-on with the 

key “Go”

 of the 

digital command

 

station

. After 

switching-on 

the 

green LED

 of the 

DB-4

 will 

glow

 and 

the unit will 

supply digital current

 to the connected track section. 

 
The 

DigitalBooster DB-4 

will be 

automatically switched-off 

if a 

short circuit 

will occur 

at the track. The 

green LED switches off

 and the 

red LED will glow constant.

 The 

DB-4

 will report the 

short circuit

 via the employed 

booster bus

 to the 

digital command 

station

. Those will switch to “

Stop

”. 

 
After 

removing

 the 

short circuit

 you can switch-on again the digital current to the track 

with 

the key

 

“Go”

 
If the current 

exceeds 2.5 Ampere

 within the track section the 

DigitalBooster DB-4

 will 

switch-off as well and is reporting this 

overload

 to the digital command station which will 

switch to 

“Stop”

 
 
 

6. Adjusting Operation Modes with Jumper:

 

 
The  various 

operation  modes

  and 

functions

  of  the 

DigitalBooster  DB-4

  can  be 

adjusted with the 

jumpers J1 to J5

 
6.1. Select the Maximum Digital Current to 2.5 or 4.5 Ampere:

 

 
The 

Jumper J5 

has been

 set ex-factory. 

The

 DigitalBooster DB-4 supplies

 with this 

setting a 

maximum output current of 2.5 Ampere

 to the track. 

 
This 

limitation

 is 

suitable

 for the 

gauge N

 to prevent the 

excessive overload

 to 

tracks

vehicle wheels

 and 

current transmittal

 in case of a 

short circuit

 

 

Содержание 080073

Страница 1: ...Booster DB 4 receives the power supply not from a classical model railway transformer but from the switched mode mains power supply DB 4 PowerSupply On this unit is the stabilized digital track voltage adjustable between 15 and 24 Volt suitable for all track gauges This product is not a toy Not suitable for children under 14 years Improper use will imply danger or injuries due to sharp edges and t...

Страница 2: ...g Operation Modes with Jumper 10 6 1 Select Maximum Digital Current to 2 5 or 4 5 Ampere 10 6 2 Select data format for WatchDog and On Off switch function 11 6 3 RailCom cutout Creation or Suppression 11 6 4 Short Circuit Report to the Command Station Short Report 11 6 5 Automatic Switch On Auto Go 12 7 Addresses for WatchDog and On Off switch function 12 7 1 Common Address Section 13 7 2 Own Addr...

Страница 3: ...om DB 4 Power Supply From DB 4 Power Supply BU1 S1 DCC MM JP1 JP2 JP3 JP4 OFF ON Auto Go RailCom ShortReport red brown LED1 LED2 GO STOP Littfinski DatenTechnik LDT KL1 K J 4 5 2 5 JP5 OUT IN ST1 ST2 Rev 1 4 DB 4 BU3 BU2 C D E STOP GO KL2 KL4 KL3 Feedback A T 2 5 4 5 Ampere Booster für die Digitalformate Märklin Motorola mfx M4 und DCC 2 5 4 5 ampere booster for Märklin Motorola mfx M4 and DCC DB ...

Страница 4: ...Central Station 3 and 3 plus X Mobile Station 2 with Track Box X ECoS 1 50 000 X X ECoS 2 50 200 X X Intellibox 1 X X IB Basic X IB COM X Intellibox 2 X X EasyControl RedBox X X DiCoStation X KeyCommander X TWIN CENTER X X Roco 10761 multiMAUS X Roco 10764 multiMAUS X Fleischmann 680801 multiMAUS X Roco Fleischmann multiZENTRALEpro X Roco Fleischmann z21 and Z21 X Lenz Digital plus LZ100 X Lenz Di...

Страница 5: ...orola mfx M4 und DCC 2 5 4 5 ampere booster for Märklin Motorola mfx M4 and DCC DB 4 DigitalBooster Multi Digital Littfinski DatenTechnik LDT www ldt infocenter com Digital Profi werden braun brown J rot red K Vom DB 4 PowerSupply 2 From DB 4 PowerSupply 2 Gleisbereich 2 Track section 2 weiss white BU1 S1 DCC MM JP1 JP2 JP3 JP4 OFF ON Auto Go RailCom ShortReport red brown LED1 LED2 GO STOP Littfin...

Страница 6: ...B 4 PowerSupply 1 Gleisbereich 1 Track section 1 Von Digitalzentrale From command station Zu weiteren Boostern To further boosters C D E C D E page_1118 Connecting the DigitalBooster DB 4 with the Command Station via CDE Boosterbus and between each other The DB 4 can get as well the supply directly from the digital output of a digital command station with integrated Booster via the connection C an...

Страница 7: ...Littfinski DatenTechnik LDT KL1 K J 4 5 2 5 JP5 OUT IN ST1 ST2 Rev 1 4 DB 4 BU3 BU2 C D E STOP GO KL2 KL4 KL3 Feedback A T 2 5 4 5 Ampere Booster für die Digitalformate Märklin Motorola mfx M4 und DCC 2 5 4 5 ampere booster for Märklin Motorola mfx M4 and DCC DB 4 DigitalBooster Multi Digital Littfinski DatenTechnik LDT www ldt infocenter com Digital Profi werden braun brown J rot red K Vom DB 4 P...

Страница 8: ...rther booster 4 1 3 Conductor Track System If the manufacturer of your digital command station permits a common layout ground brown the center conductor of the 3 conductor track has to be isolated at the cross over joints from one to the next booster electrical circuit The isolated center conductor gets the supply from the connection red of the clamp KL1 of the DigitalBooster DB 4 BU1 S1 DCC MM JP...

Страница 9: ... 4 5 Ampere Booster für die Digitalformate Märklin Motorola mfx M4 und DCC 2 5 4 5 ampere booster for Märklin Motorola mfx M4 and DCC DB 4 DigitalBooster Multi Digital Littfinski DatenTechnik LDT www ldt infocenter com Digital Profi werden braun brown rot red braun brown gelb yellow Vom Modellbahntrafo From transformer KL1 KL2 KL3 KL4 BTM SG 16 18V Rev 1 1 Littfinski DatenTechnik LDT Booster Trenn...

Страница 10: ... joints This module separates electrically definite the booster sections braun brown rot red J K Vom DB 4 Power Supply From DB 4 Power Supply BU1 S1 DCC MM JP1 JP2 JP3 JP4 OFF ON Auto Go RailCom ShortReport red brown LED1 LED2 GO STOP Littfinski DatenTechnik LDT KL1 K J 4 5 2 5 JP5 OUT IN ST1 ST2 Rev 1 4 DB 4 BU3 BU2 C D E STOP GO KL2 KL4 KL3 Feedback A T 2 5 4 5 Ampere Booster für die Digitalform...

Страница 11: ...supply digital current to the connected track section The DigitalBooster DB 4 will be automatically switched off if a short circuit will occur at the track The green LED switches off and the red LED will glow constant The DB 4 will report the short circuit via the employed booster bus to the digital command station Those will switch to Stop After removing the short circuit you can switch on again ...

Страница 12: ...ed The selection with jumper J3 if the DigitalBooster DB 4 shall create or suppress a RailCom cutout is only possible if the data format for the WatchDog and On Off switch function has been set to DCC Jumper J4 removed 6 4 Short Circuit Report to the Command Station Short Report If the Jumper J1 Short Report has been set the DigitalBooster DB 4 will report a short circuit within the connected trac...

Страница 13: ...y addresses turnout addresses which are used as well for the switching of turnouts or signals Accessory addresses are combined at groups of four The addresses 1 to 4 are forming the first group the addresses 5 to 8 the second group etc The highest valid four fold address group for the programming of the DigitalBooster DB 4 is for Märklin Motorola data format the group 313 to 316 and for the DCC da...

Страница 14: ...switch function the DigitalBooster DB 4 will occupy 4 accessory or turnout addresses WatchDog On Off sw Funktion inactivated not used Stop not used round red round red round red round red 1 2 3 4 straight green straight green straight green straight green activated not used Go not used WatchDog On Off sw Function With the above table has been the DigitalBooster DB 4 programmed for the WatchDog and...

Страница 15: ...l glow Depress 1x short the key S1 next to the jumpers of the DB 4 Now the green LED flashes This indicates that the DB 4 is in the programming mode for the address section of the On Off switch function During the programming process is the track section which is connected to the DB 4 switched voltage free 2 Switch now one turnout from the group of four which has been selected for the address sect...

Страница 16: ...ressing again the programming key S1 The programmed addresses are now permanently stored but can be changed at any time by repeating the programming process Now the green LED will glow and the track section which is connected to the DB 4 will get supply of digital voltage 8 WatchDog Communication with the Model Railway Software If your model railway software supports the WatchDog Function of the D...

Страница 17: ... address 2 round of the address block programmed for the On Off switch function The DigitalBooster DB 4 can be switched On via the basic address 2 straight WatchDog or On Off sw Function inactive not used Stop not used round red round red round red round red 1 2 3 4 straight green straight green straight green straight green WatchDog or not used Go not used inactive On Off sw Funktion The On Off s...

Страница 18: ...o Go RailCom ShortReport red brown LED1 LED2 GO STOP Littfinski DatenTechnik LDT KL1 K J 4 5 2 5 JP5 OUT IN ST1 ST2 Rev 1 4 DB 4 BU3 BU2 C D E STOP GO KL2 KL4 KL3 Feedback A T 2 5 4 5 Ampere Booster für die Digitalformate Märklin Motorola mfx M4 und DCC 2 5 4 5 ampere booster for Märklin Motorola mfx M4 and DCC DB 4 DigitalBooster Multi Digital Littfinski DatenTechnik LDT www ldt infocenter com Di...

Страница 19: ...N 16 channel feedback module Rev 1 0 BU1 BU2 s88 N OUT IN s88 N OUT Digital Profi werden www ldt infocenter com Littfinski DatenTechnik LDT 16 Rückmeldeeingänge für den s88 Rückmeldebus Rückmeldemodul RM 88 N s88 N Feedback report for Booster Management via RM 88 N s88 feedback bus 10 9 11 8 7 6 5 4 3 2 1 12 13 14 15 16 Littfinski DatenTechnik LDT RS 16 O Rev 2 0 LED1 S1 Ref K R J S 14 18V 16 galv...

Страница 20: ...ik LDT Bühler electronic GmbH Ulmenstraße 43 15370 Fredersdorf Germany Phone 49 0 33439 867 0 Internet www ldt infocenter com Subject to technical changes and errors 07 2019 by LDT Märklin and Motorola are registered trademarks RailCom is a registered trademark from the company Lenz Elektronik Giessen Germany ...

Отзывы: