SAFETY INSTRUCTIONS

1. Please read these safety instructions carefully.
2. Keep this User's Manual for future reference.
3. Unplug the equipment from the AC power supply before cleaning.
4. Do not use liquid or aerosol cleaners. Do not allow the unit to get wet.
5. Keep this equipment away from humidity.
6. Lay this equipment on a reliable flat surface before setting it up. If you don’t do so, the

equipment can fall down and get damaged. 

7. Place the power cord so that it is not likely to be walked on or pinched by having objects

placed on it.

8. Always take into account all warnings and equipment precautions.
9. In order to avoid electric overload, unplug the equipment from the wall outlet if it is not

going to be used for several days. Never pour liquid into the grilles, it could cause fire or
electric shock.

10. Do never open the equipment. For safety reasons, the equipment should only be opened

by qualified staff.

11. Pay attention to polarity when using a DC power supply. Reverse polarity may damage the

equipment or the power supply.

12. If any of the following situation arises, get the equipment checked by a service technician:

a) The cable or power plug is damaged.
b) Liquid was poured into the equipment.
c) The equipment has been exposed to moisture. 
d)  The equipment has not been working well or you cannot get it work according to this
manual.
e) The equipment have fallen down and it is damaged.
f)  The equipment has obvious sign of breakage 

13. Disconnect the audio inputs and outputs while making connections. Make sure to use the

proper cables to make the connections.

Содержание LDAVAP1

Страница 1: ...Model VAP 1 User s Manual...

Страница 2: ......

Страница 3: ...t if it is not going to be used for several days Never pour liquid into the grilles it could cause fire or electric shock 10 Do never open the equipment For safety reasons the equipment should only be...

Страница 4: ......

Страница 5: ...ING 9 3 2 4 DEACTIVATING EMERGENCY CONDITIONS 9 3 2 5 EVENT LAUNCHING 9 3 3 FAULT 9 3 3 1 MUTING FAULT CONDITION 10 3 3 2 RESETING FAULT CONDITION 10 3 4 TESTING 10 4 CONNECTION AND SETTING UP 10 4 1...

Страница 6: ......

Страница 7: ...notices and the issuing of alert and evacuation messages through up to 56 selection memories of PA zones in a NEO system FUNCTIONS 1 Up to 56 zone memories with 8 addressing zones per memory 448 zones...

Страница 8: ...hen the equipment is remotely controlled from the system controller or from another VAP 1 with higher priority This indicator is deactivated automatically when it starts to operate from the VAP 1 Ambe...

Страница 9: ...corded messages of the system and the emergency microphone h EVAC EVACUATION Active on when the message that is being issued is intended for the evacuation of the voice alarm zone or zones selected Re...

Страница 10: ...e equipment It allows to confirm that the indication of an emergency or fault condition has been noticed By pressing it the audible emergency or fault warning will be muted 2 2 4 EVAC MSG The EVAC MSG...

Страница 11: ...terminator selector EOL is located in the middle of the rear part of the equipment It allows the activation deactivation of the bus terminator This control must be active when the equipment occupies...

Страница 12: ...etermined by the selected identifier So we have ID 0 Memories 1 8 ID 1 Memories 9 16 ID 2 Memories 17 24 ID 3 Memories 25 32 ID 4 Memories 33 40 ID 5 Memories 41 48 ID 6 Memories 49 56 ID 7 Memories 5...

Страница 13: ...bus is 1000m 3280ft Mark Description Type Signals Activation BUS ACSI Line level balanced audio Control bus and supply I O Protocol N A Table 1 ACSI Bus Connection NOTE This connection is not compatib...

Страница 14: ...de with a miniUSB A male cable provided with the equipment 2 3 3 PORTS FOR EXPANSION KEYBOARDS The equipment has a port on the right side of the unit for connecting additional keyboards Mark Descripti...

Страница 15: ...ushing the ACK key 3 2 2 ISSUING VOICE WARNING Once the emergency condition is activated you will be able to select the following options to make a voice warning Issuing a recorded warning message EVA...

Страница 16: ...that you have to select the appropriate button Then the pushed button s led flashes in green pointing out that the order has been processed If it can t be processed the REMOTE led will flash indicati...

Страница 17: ...ADDRESSING AND PRIORITY CONFIGURATION Each device has a switch priority in the bus Depending on the configured priority it will be allowed to occupy the channel while it is occupied by another device...

Страница 18: ...rm RST to cancel the address change The computer will restart with the new bus address If when starting the VAP 1 REMOTE CTRL and EMG indicators light up simultaneously there is an address conflict wi...

Страница 19: ...n the maximum or minimum volume is reached the EVAC or ALERT indicators will remain on Press the ACK button to confirm RST to cancel the change 4 5 EXPANSION KEYBOARDS CONNECTION The VAP 1 can equip u...

Страница 20: ...Illustration 11 Expansion Keyboard Connection Step 1 Adaptor Illustration 12 Expansion Keyboard Connection Step 2 Illustration 13 Expansion Keyboard Connection Step 4 Block Illustration 14 Expansion...

Страница 21: ...PDATE If an equipment Firmware update is required make sure that the update image provided matches your model If the equipment has expansion keyboards connected it is not necessary to disconnect them...

Страница 22: ...the equipment with 4 M4 screws To adjust the width of the equipment you can use expansion keyboards or rack complements The following are the different combinations of installation where the keyboard...

Страница 23: ...e equipment will indicate a link failure with the system when it detects that the transmission path is shorted or disconnected Check that the VAP 1 that does not link is the only bus that can not conn...

Страница 24: ...ACSI bus of the equipment so that the rest of the system keeps working normally 7 3 NO INDICATOR LIGHTS UP If this is the case there is probably a problem with the power supply of the equipment If the...

Страница 25: ...ss according 4 2 In case that the expansion keyboard does not work yet disconnect it from the VAP 1 and contact the support repair service 7 7 THE EXPANSION KEYBOARD DOES NOT LIGHT UP If when pressing...

Страница 26: ...Operations Wipe with a damp cloth Clean the air inputs and outputs with a vacuum cleaner Check the connections of the equipment 20 www lda audiotech com en...

Страница 27: ...Warning Indicators test Functions Prior notice tone volume control DSA Dynamic sound adjuster Directionality until 448 system zones Microphone cable length 500mm 13 75 Dimensions without microphone A...

Страница 28: ...Ver 2...