The VAP 1 has two openings at the rear part for wall mounting with self-tapping screws,
whose heads have a maximum diameter of 9 mm and 4 mm wide shank.
To install it, drill two holes on the surface where the equipment will be located. The holes
must follow the measures specified in illustration 18, where distances between holes in a VAP 1
with two expansion keyboards are shown. When mounting it is only necessary to use the openings
on the end of the set. Once the equipment is placed properly lock at the top using the accessory
provided.
7 FAULT RESOLUTIONS
7.1 THERE IS NO LINK WITH THE SYSTEM
The equipment will indicate a link failure with the system when it detects that the
transmission path is shorted or disconnected.
Check that the VAP 1 that does not link is the only bus that can not connect. If there are
more equipments in the bus with this problem, start by checking the closest to the equipment
where the bus (NEO) begins.
Check that the equipment to which the ACSI bus (NEO Controller) is connected works
properly.
Check that the last bus equipment has the "Bus Terminator" option on, according to section
Connect the auxiliary power supply provided with the equipment, in case the VAP 1 is
directly supplied from the ACSI bus
LDA Audio Tech - Severo Ochoa, 31- 29590 MALAGA, SPAIN. Tel: +34 952028805
17
User’s Manual: VAP 1
Illustration 18: Wall installation template