Fig. 13 - Entering the interface parameters

 

If you want to read out «hardware revision», for example, 
you will find a reference in the manufacturer information 
that the hardware revision number is located in register 

1030

. The terms «address» and «register» are sometimes 

used interchangeably. 

 

In the program you also enter: 

 

Address: 

 

1030

 (no offset or offset=0) 

 

Value/data type: 

16 bit

 (if necessary) 

Function: 

 

0x03

 (read access) 

 

 

Now start the requirement diagram with a «SEND» command or 

similar 

 

 

 

Fig. 14 - Reading out a register value

 

As a result, the charging controller returns the revision number 

that is displayed in the software (in the example here, «5»

).

 

Use this procedure to set register «4010» to «1», for ex-
ample, in order to allow vehicles with charging status «D» 
(ventilation required) without error messages (see point 
2.1). 

 

5.  Monitoring software 

 

Follow the steps to establish a connection as described under 
4.2.  You can download 

at the time this document was cre-

ated

  the «

EV CC Device Monitor

» program from PHŒNIX 

CONTACT  in order to display various information directly and 
make changes. 

Caution: improper handling can put the de-

vice in a state that no longer permits a factory reset!

 

Start the program, agree to the licence then enter the interface 
parameters and click the button «Connect». Available parame-
ters will be shown automatically, changing parameters is simply 
made by entering and confirming the new value. 

 

 

6  Maintenance

 

 

The device does not require special maintenance. Only the test 
button of residual current circuit breaker 

13

  must be pressed 

every month. 

 

7  Technical data 

 

Power supply: 3x400 VAC, 50 Hz, 16 A 

 

Connection CEE socket 400 V/16 A, 6h 

 

Output voltage: 3x400 VAC, 50 Hz, 2 A 

 

Connection CEE plug 400 V/16 A, 6h 

 

Charging socket: Type 2, 16 A 

 

Weight: approx. 25 kg 

 

Protection class 1 

 