BUILT-IN APPLICATION REQUIREMENTS AND CUTOUTS
Installation Method #2 for the Open Hearth Series grills uses a front/vertical gas pipe exit point into the masonry island.
The masonry should be laid so that there is a vertical notch running from top to bottom on both sides of the cutout. A
hole is created at the bottom of the cutout for the gas line exit. This product is shipped with the gas side on the left and
the ‘stubbed’ side on the right. The gas exit side can be changed to the right side by simply reversing the fittings. This
notch should measure 1-1/2” x 1-1/2” and run vertically on the entire height of the cutout on both front edges. With this
installation method, the grill is inserted into place from the TOP down. After the grill is in place and connected, the front
portion of the notch can be covered with a cover stones as shown in the above diagram.
Cut-Out Dimensions
Grill Model
Dim ‘A’
Dim ‘B’
Dim ‘C’
A4TS or A4TS/SS
65-1/2”
21”
7”
A3TS or A3TS/SS
49-1/4”
21”
7”
A2TS or A2TS/SS
33”
21”
7”
A1TS or A1TS/SS
16-3/4”
21”
7”
A1TS/B60
16-3/4”
21”
7”