1.
Remove the oil maintenance cover after
unscrewing the fixing bolt.
2.
Clean any dirt from the spark plug cap and
spark plug base.
3.
Remove the spark plug cap.
4.
Using socket wrench to loose and remove the
spark plug.
5.
Observe whether the spark plug and spark
plug gasket are damaged, if necessary, replace
them.
6.
Check spark plug gap. If necessary, carefully
bend one end of the electrode to adjust the
clearance.
SPARK PLUG GAP: 0.6MM - 0.8MM
7.
Carefully thread the plug into the engine by
hand.
8.
After the spark plug is seated, use spark plug
wrench to tighten the plug.
SPARK PLUG TIGHTEN TORQUE: 20-25 N.M
9.
Attach the spark cap to the plug and connect
the spark plug wire to the plug.
WARNING
Only use the recommended spark plug or equivalent.
DO NOT use spark plugs that have improper heat
range.
10. Install Oil maintenance cover.
SPARK KILLER
(IF APPLICABLE)
1.
Allow the generating set to cool completely
before servicing the spark arrester.
2.
Remove the muffler blind window first.
3.
Remove the spark arrester screen.
4.
Carefully remove the carbon deposits from the
spark arrester screen with a wire brush.
5.
Replace the spark arrester if it is damaged.
6.
Reinstall the spark arrester in the muffler and
reinstall the muffler blind window.
SPEED
The speed has been pre-set at the factory and should
rarely require readjustment. Consult your local
authorized LawnMaster dealer for such needs.
WARNING
Unapproved adjustment will damage your engine
and/or your electrical devices and void your war-
ranty.
ADJUSTMENT
There has no other service and/or adjustment need
for your generator. Unapproved adjustments or
tampering can damage your generator and your elec-
trical devices and will void your warranty. Contact
your local dealer for such needs.
WARNING
Tampering with the factory set governor will damage
your generator and void your warranty.
STORAGE & TRANSPORTATION
STORAGE
The generating set should be started at least once
every 2 weeks and allowed to run for at least 20
minutes. Follow the instructions below for longer term
storage if the generating set will be out of service for 2
months or more.
WARNING
FIRE OR EXPLOSION
Gasoline is highly flammable and extremely explosive.
Empty the fuel tank and shut off fuel valve before
storing or transporting this generating set.