![LawnMaster LGBQH9200 Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/lawnmaster/lgbqh9200/lgbqh9200_safety-and-operating-manual_3972728013.webp)
13
A STEELFORT PRODUCT
WARNING
Remote transmitter and genrator learning
The generator and the remote controller have been
successfully matched at the factory, and users do not
need to perform matching when use.
MATCHING WIRELESS REMOTE CONTROL
(IF APPLICABLE)
1.
Turn the Start/Stop switch to “RUN” position
2.
Press and hold the learning button until a blue
light comes on and then release, the blue light
stays on.
3.
Press and hold the “OFF” button of the remote
control until the learning lamp flashes 1 time
and then release it.
4.
Press and hold the “ON” button of the remote
control until the learning lamp flashes for 1 time
and then release.
5.
Press and hold the learning button until it goes
out and then release it.
MANUAL START
When starting engine, grasp the recoil starter handle
and pull slowly until resistance is felt. Then pull
rapidly to advoid kickback.
WARNING
Check starter cord conditions before operating. Have
it replaced immediately by your local service dealer if
cord is frayed.
KICKBACK
Rapid retraction of the starter cord will pull hand and
arm towards the engine faster than you can let go.
Unintentional startup can result in entanglement,
traumatic amputation or laceration. Broken bones,
fractures, bruises or sprains could result.
When the battery power of the generator is too low
to start, please operate the choke handle as the
following figure to start the generator.
CAUTION
Choke plate should be setting in different width due
to temperature and other factors.
1.
Remove the oil maintenance cover.
2.
Move the carburetor choke lever to the right to
close the choke.
3.
When starting the engine, grasp the recoil
starter handle and pull slowly until resistance is
felt. Then pull rapidly to avoid kickback.
4.
After the generator has started, move the
carburetor choke lever to the left to open the
choke.
After completing the above operations, the generator
can be connected to electrical equipment.
CAUTION
Do not restart the generator without removing the
fault. It is strictly forbidden to start the generator
after using other batteries without authorization.
WARNING
It is prohibited to start or close the generating
set when the output terminal of generating set is
connected to an electric device and the electric
device is in “ON” state.