Technical support maintenance manual
Rel. 0.00 / February 2020
38
12.13. REMOVING THE POWER CABLE CONNECTOR
Figure A
: disconnect the two elec-
trical connections indicated by the
CPU board and the grounding ca-
ble (heater side).
Figure B
: lift the indicated tabs
(two on one side of the unit, one
on the other) and pull out the con-
nector (
1
).
D
12.14. EXTRACTING THE DISPENSING UNIT
Warning
Wait for the boiler to cool off before performing these operations. DANGER OF BURNS.
Figure A
: disconnect the indicat-
ed electrical connection from the
CPU BOARD.
Extract the wires from their rela-
tive constraints, taking care not to
damage them.
A
B
1
A