Technical support maintenance manual
Rel. 0.00 / February 2020
34
Figure C
: remove the two screws
and remove the heater.
B
12.7. Y-VALVE DISMANTLING
Figure A
: disconnect the water
connections and unscrew the
screw.
F
B
Pull out the Y-valve (
1
).
12.8. REMOVING THE FLOWMETER
Figure A
: in the base of the ma-
chine, press down on the indicat-
ed interlocking lever and slightly
extract the volumetric meter (
1
).
Disconnect the electrical wiring
and the two water connections.
Then extract the flowmeter.
C
A
1
A
1