background image

LAUNCH                       KWA-300 3D Wireless Wheel Aligner                             FAQ

 

5-1 

Frequently Asked 
Questions (FAQ) 

 

Industrial Computer Cannot 
Start Up, Without Any Prompts. 

z

 

Check the power socket and plug.  

z

 

Check the connection. Check the power switches 
of main unit and monitor. Check the indicator.   

z

 

Check the contrast and brightness.  

Computer Cannot Enter 
Windows XP.   

z

 

The hardware start files are lost. 

z

 

BISO setting error.  

z

 

Hardware malfunction.   

Mouse and Keyboard does not 
Respond 

z

 

Check the connection of mouse and/or keyboard.  

z

 

Check the matching of mouse and/or keyboard to 
main unit.   

z

 

Mouse or keyboard damaged.   

z

 

Mouse ball too dirty.  

Printer does not Respond 

z

 

Check connection of printer cables.   

z

 

Check printer drive program and settings.   

z

 

Check computer virus.   

KWA-300 3D Program Does Not 
Run  

z

 

Program file lost or error.   

z

 

Program registry list damaged. 

Why the blocking tip box does 
not appear when you turn the 
steering wheel and block the 
rear target? 

It is normal. The test result will not be influenced 
without tip box, but please do not block any one of the 
front targets when you test the extremum point and 
toe-out on turns. 

When you turn the steering 
wheel, the tip box appears in 
case of the light path has been 
blocked, how to handle it? 

If the tip box appears among the 20

º 

area, please stop 

turning the steering wheel, move the blocks away and 
then continue to turn the steering wheel. 

Why does it have obvious 
difference between left and right 
minimum turning radius after 
alignment? 

It is caused by the mistaken position between the 
steering wheel and the steering column. Alignment in 

this system is performed in the normal case of Steering 
Wheel Centered, i.e. it is based on Steering Wheel 
Centered, so it is necessary to ask the user about the 
maintenance and use history of the steering wheel, 
eliminating the interference of the mistaken position 

between the steering wheel and the steering column, 
centering the steering wheel according to the 
experience. 

Содержание KWA-300

Страница 1: ......

Страница 2: ...ten permission to use Materials on this manual for purposes or for all other questions relating to this manual Copyright Information Copyright 2010 by LAUNCH TECH CO LTD All rights reserved No part of...

Страница 3: ...tion z The precision position calibration has been performed for the cameras after first installation the user can not move or wobble the camera post during or after using it z Without approval of the...

Страница 4: ...e of the safety signs exists in the prevention of personal injuries If the warning triangle with the wording danger is on a safety notice hazards for the machine material and the environment are not e...

Страница 5: ...el with key tools Never spray the housing of electrical equipment with a hose when cleaning Observe environmental regulations The legal regulations for waste prevention and proper recycling disposal m...

Страница 6: ...e Model 4 1 Rolling Run out Compensation 4 4 Caster Swing 4 4 Rear axle measurement 4 6 Front axle measurement 4 7 Print Report 4 9 Quick Measurement 4 10 Additional Measurement 4 10 System Management...

Страница 7: ...toe out on turns wheelbase difference track width difference etc They are designed mainly to improve the steering performance and driving stability of the vehicle and reduce tire wear Toe in and Toe o...

Страница 8: ...steering will normally be designed with positive caster Toe out on Turns Toe out on turns is defined as the difference of the steering angle between the two front wheels when turning left or right by...

Страница 9: ...is negative The angle between the bisector of the track width difference angle and the thrust line is axle offset angle Axle offset angle The relative offset in lateral direction between front and re...

Страница 10: ...t animation and HELP information z Provide real time help with help system z Provide the function of data back up and restoration and of software upgrade Specification Item Resolution Test Range Total...

Страница 11: ...WA 300 3D It consists of a computer power supply system and interfaces Its function is to execute the operation commands process the data and display the information together with the original data of...

Страница 12: ...inside the computer and the keyboard is installed on the keyboard drawer The power supply assembly includes power lead power socket and the power supply master switch The power supply master switch bu...

Страница 13: ...herwise distortion may be caused and the test result may be influenced Communication Cables There are 4 signal cables and 2 power supply cables for infrared light between the main unit and the cameras...

Страница 14: ...LAUNCH KWA 300 3D Wheel Aligner Structures 2 3 Brake Pedal Depressor KWA 300 3D has a brake pedal depressor as shown in Fig 2 7 It is used to hold the brake pedal down Fig 2 7 Brake pedal depressor...

Страница 15: ...e rod end and steering mechanism for any looseness or wear Then check to see if the tire pressure tire track widths of the left and right wheels are alike Wheel Alignment Checking Perform the wheel al...

Страница 16: ...lling accidentally Please see Fig 4 1 Fig 4 1 5 Insert the power plug of the wheel aligner into the standard 3 pole power receptacle Program Operation Turn on the power switch start the computer and e...

Страница 17: ...t operating procedure 2 The form currently provided is the same form with Commonly Used Data Management in the System Management interface in the same way you can click button to add the standard data...

Страница 18: ...re not within the standard range please check the vehicle status and adjust the corresponding components to keep 4 Height Measurement Values within the standard range Click NEXT after finished 4 When...

Страница 19: ...when performing Rolling run out compensation operation causing the unstable axis 3 The line of sight of any camera cannot be blocked during pulling and pushing vehicle 4 Keep the force for pushing an...

Страница 20: ...ase center the steering wheel The system will automatically return to the next page to check the measurement result The interface is as shown in Fig 4 14 Fig 4 14 Measurement for Max steering angle Ac...

Страница 21: ...indicates that this measured parameter has not the standard specification Rear axle measurement This interface can provide the real time result related to rear axle measurement the operator can compar...

Страница 22: ...ding to the operating methods in the HELP interface The interface is as shown in Fig 4 23 Fig 4 23 Lift up the vehicle body Sometimes it is required to lift the vehicle body up in order to be convenie...

Страница 23: ...e prompts on the screen The software will automatically compensate the offset of inclinometer in order to realize accurate adjustment Attention After adjustment please remember to click button and the...

Страница 24: ...r the interface of Client Management and then the corresponding Client information can be selected If information of this client is not available in Client Management it must be added first before sel...

Страница 25: ...ed to Figure Format The fig format data display interface provides the display for thrust angle The interface is as shown in Fig 4 34 Fig 4 34 Note 1 This interface provides only the functions of the...

Страница 26: ...the information of maintenance station be displayed on the report form printed out and is convenient for your data management and tracing operation The interface is as shown in Fig 4 39 Fig 4 39 Sett...

Страница 27: ...e world and the contents in database can be updated in time via system upgrade In addition this interface provides the function of adding the user defined data The operator can add by him self or her...

Страница 28: ...r the first time Special version for experienced operator too much HELP information will on the contrary become encumbrance so this version provides the necessary HELP information only to make the ope...

Страница 29: ...information The interface is as shown in Fig 4 49 Fig 4 49 Operating procedures 1 Backup Click button find the position of the file you expect to save in pop up dialogue box The interface is as shown...

Страница 30: ...ularly too so as to be convenient to repair and maintain the equipment Target Monitoring Target monitoring needs to be performed before test click the icon of Target Monitor the screen will display th...

Страница 31: ...t This list can display the alignment test records for one time or many times of the client selected from Client list Print To print the alignment data of the vehicle under test with form or figure fo...

Страница 32: ...r when you turn the steering wheel and block the rear target It is normal The test result will not be influenced without tip box but please do not block any one of the front targets when you test the...

Страница 33: ...h dipped with an appropriate amount of the neutral detergent or the absolute alcohol to wipe the surface of target lightly if there are some smuts on it z Don t disassemble the targets and clamps to a...

Страница 34: ...entation or warranty concerning LAUNCH automotive meters except as stated herein Disclaimer THE ABOVE WARRANTY IS IN LIEU OF ANY OTHER WARRANTY EXPRESSED OR IMPLIED INCLUDING ANY WARRANTY OF MERCHANTA...

Отзывы: