LAUNCH                             KWA-300 3D Wheel Aligner                Operation Instructions

 

4-7 

Click 

  pushbutton to select the parameters of 

standard vehicle model. If the parameter values of 
wheelbase and front/rear track width are contained in 
the standard database, each angle value displayed on 
the screen will automatically be converted into length 
value with the unit of mm. The interface is as shown in 
Fig.4.22. 

 

Fig.4.22 

 

Note: The system provides the dynamic 
measurement and display for these special values, 
but the measurement result will not be saved in the 
database. 

 

[HELP for vehicle adjustment]: Click this button, the 
screen will pop up an interface of [HELP for vehicle 
adjustment], the different toe-in and camber adjusting 
methods for various vehicle models have been 
enumerated in this interface for vehicle adjustment, the 

operator can perform the toe-in and camber adjustment 
operation according to the operating methods in the 
HELP interface. The interface is as shown in Fig.4.23. 

 

Fig.4.23 

 

[Lift up the vehicle body]: Sometimes it is required to lift 
the vehicle body up in order to be convenient to adjust 
front/rear camber and caster. The system can provide 

Lift-up adjustment function. When the vehicle body is 
lifted up, the measured data can be displayed normally 
on the interface, and user may adjust the alignment 

geometry according to the prompts on the interface.   

 

Fig.4.24 

 

Attention: After adjustment, please remember to 

click 

 button, and then put down the vehicle 

body according to the prompts on the screen. If the 

lift is not put down, it will be limited to select the 
other interfaces (except for [Front axle measurement] 
interface) as shown in Fig.4.25. 

 

Fig.4.25 

Front axle measurement 

This interface can provide the real-time result related to 
front axle measurement, the operator can compare the 
measurement result with the reference data while 
adjusting the vehicle, until the vehicle is adjusted to the 
best status. The interface is as shown in Fig.4.26. 

 

Содержание KWA-300

Страница 1: ......

Страница 2: ...ten permission to use Materials on this manual for purposes or for all other questions relating to this manual Copyright Information Copyright 2010 by LAUNCH TECH CO LTD All rights reserved No part of...

Страница 3: ...tion z The precision position calibration has been performed for the cameras after first installation the user can not move or wobble the camera post during or after using it z Without approval of the...

Страница 4: ...e of the safety signs exists in the prevention of personal injuries If the warning triangle with the wording danger is on a safety notice hazards for the machine material and the environment are not e...

Страница 5: ...el with key tools Never spray the housing of electrical equipment with a hose when cleaning Observe environmental regulations The legal regulations for waste prevention and proper recycling disposal m...

Страница 6: ...e Model 4 1 Rolling Run out Compensation 4 4 Caster Swing 4 4 Rear axle measurement 4 6 Front axle measurement 4 7 Print Report 4 9 Quick Measurement 4 10 Additional Measurement 4 10 System Management...

Страница 7: ...toe out on turns wheelbase difference track width difference etc They are designed mainly to improve the steering performance and driving stability of the vehicle and reduce tire wear Toe in and Toe o...

Страница 8: ...steering will normally be designed with positive caster Toe out on Turns Toe out on turns is defined as the difference of the steering angle between the two front wheels when turning left or right by...

Страница 9: ...is negative The angle between the bisector of the track width difference angle and the thrust line is axle offset angle Axle offset angle The relative offset in lateral direction between front and re...

Страница 10: ...t animation and HELP information z Provide real time help with help system z Provide the function of data back up and restoration and of software upgrade Specification Item Resolution Test Range Total...

Страница 11: ...WA 300 3D It consists of a computer power supply system and interfaces Its function is to execute the operation commands process the data and display the information together with the original data of...

Страница 12: ...inside the computer and the keyboard is installed on the keyboard drawer The power supply assembly includes power lead power socket and the power supply master switch The power supply master switch bu...

Страница 13: ...herwise distortion may be caused and the test result may be influenced Communication Cables There are 4 signal cables and 2 power supply cables for infrared light between the main unit and the cameras...

Страница 14: ...LAUNCH KWA 300 3D Wheel Aligner Structures 2 3 Brake Pedal Depressor KWA 300 3D has a brake pedal depressor as shown in Fig 2 7 It is used to hold the brake pedal down Fig 2 7 Brake pedal depressor...

Страница 15: ...e rod end and steering mechanism for any looseness or wear Then check to see if the tire pressure tire track widths of the left and right wheels are alike Wheel Alignment Checking Perform the wheel al...

Страница 16: ...lling accidentally Please see Fig 4 1 Fig 4 1 5 Insert the power plug of the wheel aligner into the standard 3 pole power receptacle Program Operation Turn on the power switch start the computer and e...

Страница 17: ...t operating procedure 2 The form currently provided is the same form with Commonly Used Data Management in the System Management interface in the same way you can click button to add the standard data...

Страница 18: ...re not within the standard range please check the vehicle status and adjust the corresponding components to keep 4 Height Measurement Values within the standard range Click NEXT after finished 4 When...

Страница 19: ...when performing Rolling run out compensation operation causing the unstable axis 3 The line of sight of any camera cannot be blocked during pulling and pushing vehicle 4 Keep the force for pushing an...

Страница 20: ...ase center the steering wheel The system will automatically return to the next page to check the measurement result The interface is as shown in Fig 4 14 Fig 4 14 Measurement for Max steering angle Ac...

Страница 21: ...indicates that this measured parameter has not the standard specification Rear axle measurement This interface can provide the real time result related to rear axle measurement the operator can compar...

Страница 22: ...ding to the operating methods in the HELP interface The interface is as shown in Fig 4 23 Fig 4 23 Lift up the vehicle body Sometimes it is required to lift the vehicle body up in order to be convenie...

Страница 23: ...e prompts on the screen The software will automatically compensate the offset of inclinometer in order to realize accurate adjustment Attention After adjustment please remember to click button and the...

Страница 24: ...r the interface of Client Management and then the corresponding Client information can be selected If information of this client is not available in Client Management it must be added first before sel...

Страница 25: ...ed to Figure Format The fig format data display interface provides the display for thrust angle The interface is as shown in Fig 4 34 Fig 4 34 Note 1 This interface provides only the functions of the...

Страница 26: ...the information of maintenance station be displayed on the report form printed out and is convenient for your data management and tracing operation The interface is as shown in Fig 4 39 Fig 4 39 Sett...

Страница 27: ...e world and the contents in database can be updated in time via system upgrade In addition this interface provides the function of adding the user defined data The operator can add by him self or her...

Страница 28: ...r the first time Special version for experienced operator too much HELP information will on the contrary become encumbrance so this version provides the necessary HELP information only to make the ope...

Страница 29: ...information The interface is as shown in Fig 4 49 Fig 4 49 Operating procedures 1 Backup Click button find the position of the file you expect to save in pop up dialogue box The interface is as shown...

Страница 30: ...ularly too so as to be convenient to repair and maintain the equipment Target Monitoring Target monitoring needs to be performed before test click the icon of Target Monitor the screen will display th...

Страница 31: ...t This list can display the alignment test records for one time or many times of the client selected from Client list Print To print the alignment data of the vehicle under test with form or figure fo...

Страница 32: ...r when you turn the steering wheel and block the rear target It is normal The test result will not be influenced without tip box but please do not block any one of the front targets when you test the...

Страница 33: ...h dipped with an appropriate amount of the neutral detergent or the absolute alcohol to wipe the surface of target lightly if there are some smuts on it z Don t disassemble the targets and clamps to a...

Страница 34: ...entation or warranty concerning LAUNCH automotive meters except as stated herein Disclaimer THE ABOVE WARRANTY IS IN LIEU OF ANY OTHER WARRANTY EXPRESSED OR IMPLIED INCLUDING ANY WARRANTY OF MERCHANTA...