LAUNCH KES-200 4Channel Oscilloscope
B-4
main cable when using KES-200. Connect one end of
the main cable with external power connector to the
main cable port on the KES-200.
Fig.1-03
Battery cable:
Fig.1-04. Connect the red clip of battery
cable to the positive pole of battery and black clip to the
negative pole, and connect the other end of the battery
cable onto the power connector of the main cable, so as to
get power from the vehicle battery.
Fig.1-04
Oscilloscope cable:
Fig.1-05 It is used for functions of
multimeter, oscilloscope, or primary ignition waveform.
Two types of oscilloscope cables are provided, one is
equipped with probes, and the other with clips.
Fig.1-05
Secondary signal cable:
Fig.1-06. It is similar to the
oscilloscope cable but without probes. While using,
connect the red clip to the secondary high-tension cable
of the engine.
Fig.1-06
Cylinder 1 signal cable:
Fig.1-07. For testing ignition
waveform, clip the holder of the cable to secondary
high-tension cable of cylinder 1 with the side labeled
with “SPARK PLUG SIDE” facing the engine.
Fig.1-07
Ground cable:
Fig.1-08. Used for multimeter,
oscilloscope and ignition waveform test. Clip one end of
the cable to any metal part of the vehicle and the other
end to Channel 5 on the main unit.
Fig.1-08
Printer cable:
For data printing, connect the 15PIN end
of the print cable to the “PC/Printer” interface on the
right side of the main unit and the other end (25PIN) to
a printer.
Note: Never connect the printer cable until the
main unit is turned on. Otherwise, the main unit