- 8 -
LED AND KEY FUNCTION
LED
Main function
Secondary function *
NET
net weight (semi-automatic tare or preset tare)
LED lit: input 1 closed
zero (deviation from zero not more than ±0.25 divisions) LED lit: input 2 closed
stability
LED lit: input 3 closed
kg
unit of measure: kg
LED lit: output 4 closed
g
unit of measure: g
LED lit: output 5 closed
W1
LED lit: output 1 closed
W2
LED lit: output 2 closed
W3
LED lit: output 3 closed
*) To activate the secondary LED function, during weight display press and hold down MENU and
▲
keys at the same time (press MENU immediately followed by
▲
).
KEY Short
press
Long press
(3 s)
Into menus
Semi-automatic zero Tare
resetting
Cancel or return to previous
menu
Gross
Net
Net
Gross
Select figure to be modified
or go to previous menu item.
Prints actual weight
mV load cell test
Modify selected figure or go
to next menu item
Setting setpoint and hysteresis
Confirm or enter in
submenu
+
Setting general parameters (press
immediately followed by
)
+
Setting preset tare (press
immediately followed by
)
Into menus LEDs light up in sequence to indicate that it is not displaying a weight.