- 7 -
LED AND KEY FUNCTION
LED
Main function
Secondary function *
NET
net weight LED: net weight display (semi-
automatic tare or preset tare)
LED lit: input 1 closed
0
zero LED (deviation from zero not more than +/-
0.25 divisions)
LED lit: input 2 closed
stability LED
LED lit: output 1 closed
kg
unit of measure: kg
LED lit: output 2 closed
g
unit of measure: g
LED lit: output 3 closed
L other
unit of measure
LED lit: output 4 closed
*) To activate the secondary LED function, during weight display press and hold down MENU and
▲
keys at the same time (press MENU immediately followed by
▲
).
KEY Short
press
Long press
(3 s)
Into menus
Tare resetting
Cancel or return to previous
menu
Gross
Net
Net
Gross
Select figure to be modified or
return to previous menu item
mV load cell test
Modify selected figure or go
to next menu item
Setting setpoints and delay
Confirm or enter in submenu
+
Setting general parameters
(press
immediately
followed by
)
+
Setting preset tare (press
immediately followed by
)
Into menus LEDs light up in sequence to indicate that it is not displaying a weight.