- 12 -
CD-
Elementy systemu domofonowego
2500
is switched off. Recovery of the power supply results in setting the lower limit to
value 1 and the upper limit to value 254.
The installation procedure P-1 allows the system to be installed by one person.
There is no necessity for assistant operating the control unit at the street-door. With
the keypad installed and put into opertion and cables between floors installed, further
works (installation and checking of uniphones in flats) can be accomplished with
operative P-1 procedure having the possibility of checking of the installed uniphones.
The P-1 procedure can be ended by C+1 After simultaneous touch on the two
symbols the [P- ] level is restored.
P-2 Setting door phone parameters.
This procedure is used to define parameters of the system operation. Level P-2
makes also accessible subprograms defining the system configuration.
2
x
C
1
2
3
new
value
old
value
x-number
of
procedure
The first 8 operations are used to set basic operation times.
When a new parameter is entered its value is compared by the system with maximum
value permissible for a given function.
Maximum values are defined as follows:
- ringing time:
255
- after-ringing time:
255
- talking time:
255
- catch operation time:
20
- ringing to removed handset duration:
15
- ringing signal duration:
255
When any attempt is made to enter a parameter value exceeding the above specified
maximum value this attempt will be ignored
Structure of the instructions is as follows:
P-2-1 -uniphone ringing time
P-2-2 -after-ringing wait time
P-2-3 -talking time
P-2-4 -electric catch operation time
P-2-5 -uniphone ringing time with removed handset
P-2-6 -first ringing tone
P-2-7 -second ringing tone
P-2-8 -single ring signal time
P-2-9 -door phone operation configuration