Power consumption:

 450W 

 

Size:

 800 x 530 x 350 mm (W x D x H) 

 

Weight:

 69kg Laser, 

total:

 96kg 

(with flightcase)

 

 

Operating temperature:

 10°-35°C 

 

Loudness:

 <70dB 

Change scanner 

1.

 

Unscrew UK M6 screws and disconnect 
signal cable. 

2.

 

Loosen M4 x 10 screw and remove galvo.  

3.

 

Insert galvo, reconnect and fix signal 
cable. 

4.

 

Rotate galvo to center projection. Fix 
galvo. 

Adjustable mirror mounts 

1.

 

Loosen setscrews, then adjust with X/Y 
adjustable screws. Make sure beam is 
centered on scanner mirrors. 

2.

 

Adjust Z-screw simultaneously. 

3.

 

Tighten setscrews. 

4.

 

When combining beams (RGY/RGB laser), 
first make sure the beams are (roughly) 
on the same spot on the mirrors/dichros. 
Then use a test pattern (e.g. rectangle) to 
do fine adjustment. For adjustments, 
always turn output power down (if 
possible). 

Troubleshooting 

Problem 

Possible reason 

Damaged part 

Replacement 

No power 

Fuse blown 

Fuse 

09-00-3001-01 

 

Power switch defective 

Power switch 

08-05-0400-03 

Power supply defective 

+-24V 

16-03-0039-00 

Power supply defective 

12V 

16-03-0019-00 

 

 

X and/or Y axis no 

deflection 

 

Scanner defective 

Galvo 

15-01-6800-00 

CPU defective 

STC89C516 

00-89C516ED-00 

 Control board defective 

Steuerung PCB 

26-2A-2009LD-00 

Power supply defective 

+-24V 

16-03-0039-00 

Scanner driver board defective 

Scanner driver board  

26-2A-6800A-00 

 
 

Laser dark or dim 

Lenses / mirrors dirty 

Clean with alcohol 

 

Laser diode defective 

Laser diode 

Inquire 

Control board defective 

Control board 

26-2A-2009LD-00 

Configuration / wrong mode 

Check configuration (see 
paragraph control panel) 

 

 

 

 

No output 

Configuration / wrong mode 

Check configuration (see 
paragraph control panel) 

 

 Control board defective 

Steuerung PCB 

26-2A-2009LD-00 

Power supply defective 

+-24V 

16-03-0039-00 

Display board defective 

Display 

26-2A-YX2012DI-00 

Pins 4 and 17 of the ILDA signal 

not connected 

See below 

 

 

Laser does not switch to ILDA mode:  

 

The interface does not connect pins 4 and 17 (Interlock) of the IDLA signal. See interface manual 

 

The cable does not connect pins 4 and 17. Use a cable that connects pins 4 and 17. 

 

Use an adapter, that connects pins 4 and 17. 

Содержание Pro-4000RGB

Страница 1: ...Pro 4000RGB User Manual Please read this manual carefully before use...

Страница 2: ...der to safeguard sufficient ventilation leave 50 cm of free space around the device Never direct the laser beam to people or animals CAUTION LASER DIODE If you open the device for cleaning always disc...

Страница 3: ...clean This unit should be keep dry do not use in the rain or damp and dusty environment don t put liquid fileld containers on the device Projector should be put in a water proof housing when operated...

Страница 4: ...me out of the opening on the front panel be careful Connectors Control panel MODE select mode or go up in menu ENTER confirm changes or go down in menu UP DOWN change DMX address Operating modes DMXAd...

Страница 5: ...eed 0 255 slow to fast 16 Point draw 0 255 slow to fast 17 Scanspeed 0 255 slow to fast 18 Pattern size 0 1 Original size 2 255 Change Maintenance cleaning Always disconnect from mains before cleaning...

Страница 6: ...switch 08 05 0400 03 Power supply defective 24V 16 03 0039 00 Power supply defective 12V 16 03 0019 00 X and or Y axis no deflection Scanner defective Galvo 15 01 6800 00 CPU defective STC89C516 00 8...

Страница 7: ...V 5V 14 X 5V 5V 2 Scanner Y 5V 5V 15 Y 5V 5V 3 Intensity Blanking 0V 2 5V 16 Intensity Blanking 0 2 5V 4 Interlock A 17 Interlock B 5 Red 0 2 5V 18 Red 0 2 5V 6 Green 0 2 5V 19 Green 0 2 5V 7 Blue 0 2...

Страница 8: ...ions and unskilled operation For service contact your dealer or Laserworld Only use Laserworld spare parts Data subject to change without notice Errors and omissions expected Laserworld Switzerland AG...

Отзывы: